EMR-4000
IM02602009E
Name
Description
Logic.LE78.Gate In1-I
State of the module input: Assignment of the Input Signal
Logic.LE78.Gate In2-I
State of the module input: Assignment of the Input Signal
Logic.LE78.Gate In3-I
State of the module input: Assignment of the Input Signal
Logic.LE78.Gate In4-I
State of the module input: Assignment of the Input Signal
Logic.LE78.Reset Latch-I
State of the module input: Reset Signal for the Latching
Logic.LE79.Gate Out
Signal: Output of the logic gate
Logic.LE79.Timer Out
Signal: Timer Output
Logic.LE79.Out
Signal: Latched Output (Q)
Logic.LE79.Out inverted
Signal: Negated Latched Output (Q NOT)
Logic.LE79.Gate In1-I
State of the module input: Assignment of the Input Signal
Logic.LE79.Gate In2-I
State of the module input: Assignment of the Input Signal
Logic.LE79.Gate In3-I
State of the module input: Assignment of the Input Signal
Logic.LE79.Gate In4-I
State of the module input: Assignment of the Input Signal
Logic.LE79.Reset Latch-I
State of the module input: Reset Signal for the Latching
Logic.LE80.Gate Out
Signal: Output of the logic gate
Logic.LE80.Timer Out
Signal: Timer Output
Logic.LE80.Out
Signal: Latched Output (Q)
Logic.LE80.Out inverted
Signal: Negated Latched Output (Q NOT)
Logic.LE80.Gate In1-I
State of the module input: Assignment of the Input Signal
Logic.LE80.Gate In2-I
State of the module input: Assignment of the Input Signal
Logic.LE80.Gate In3-I
State of the module input: Assignment of the Input Signal
Logic.LE80.Gate In4-I
State of the module input: Assignment of the Input Signal
Logic.LE80.Reset Latch-I
State of the module input: Reset Signal for the Latching
Sgen.Running
Signal: Measuring value simulation is running
Sgen.Ex Start Simulation-I
State of the module input:External Start of Fault Simulation (Using the test parameters)
Sgen.ExBlo
Module Input State: External Blocking
Sgen.Ex ForcePost-I
State of the module input:Force Post state. Abort simulation.
Sys.PS 1
Signal: Parameter Set 1
Sys.PS 2
Signal: Parameter Set 2
Sys.PS 3
Signal: Parameter Set 3
Sys.PS 4
Signal: Parameter Set 4
Sys.PSS manual
Signal: Manual switch over of a Parameter Set
Sys.PSS via Comm
Signal: Parameter Set Switch via Scada. Write into this output byte the integer of the parameter set that
should become acitve (e.g. 4 => Switch onto parameter set 4).
Sys.PSS via Inp fct
Signal: Parameter Set Switch via Input Function
Sys.Min. 1 param changed
Signal: At least one parameter has been changed
Sys.Program Mode Bypass
Signal: Short-period bypass of the Program Mode.
www.eaton.com
955
Содержание EMR-4000
Страница 61: ...EMR 4000 IM02602009E Ethernet RJ45 Terminal Marking www eaton com 61 1 8 TxD TxD RxD N C N C RxD N C N C...
Страница 423: ...EMR 4000 IM02602009E Name Description Logic LE23 Out inverted Signal Negated Latched Output Q NOT www eaton com 423...
Страница 493: ...EMR 4000 IM02602009E Motor Protection Curves Motor Protection Curve Example 1 www eaton com 493...
Страница 494: ...EMR 4000 IM02602009E Motor Protection Curve Example 2 without RTDs www eaton com 494...
Страница 495: ...EMR 4000 IM02602009E Motor Protection Curve Example 3 with RTDs www eaton com 495...