NOTE: You cannot set the SGPIO mode using iDRAC Web interface.
Setting SGPIO mode using RACADM
To configure the SGPIO mode, use the set command with the objects in the SGPIOMode group.
If it is set to disabled, it is I2C mode. If enabled, it is set to SGPIO mode.
For more information, see the
iDRAC RACADM Command Line Interface Reference Guide
available at
dell.com/idracmanuals
.
Choosing operation mode to apply settings
While creating and managing virtual disks, setting up physical disks, controllers, and enclosures or resetting controllers, before you
apply the various settings, you must select the operation mode. That is, specify when you want to apply the settings:
•
Immediately
•
During the next system reboot
•
At a scheduled time
•
As a pending operation to be applied as a batch as part of a single job.
Choosing operation mode using web interface
To select the operation mode to apply the settings:
1.
You can select the operation mode on when you are on any of the following pages:
•
Overview
→
Storage
→
Physical Disks
→
Setup
.
•
Overview
→
Storage
→
Virtual Disks
→
Create
•
Overview
→
Storage
→
Virtual Disks
→
Manage
•
Overview
→
Storage
→
Controllers
→
Setup
•
Overview
→
Storage
→
Controllers
→
Troubleshooting
•
Overview
→
Storage
→
Enclosures
→
Setup
•
Overview
→
Storage
→
Pending Operations
2.
Select one of the following from the
Apply Operation Mode
drop-down menu:
•
Apply Now
— Select this option to apply the settings immediately. This option is available for PERC 9 controllers only. If
there are jobs to be completed, then this option is grayed-out. This job take at least 2 minutes to complete.
•
At Next Reboot
— Select this option to apply the settings during the next system reboot. This is the default option for
PERC 8 controllers.
•
At Scheduled Time
— Select this option to apply the settings at a scheduled day and time:
–
Start Time
and
End Time
— Click the calendar icons and select the days. From the drop-down menus, select the time.
The settings are applied between the start time and end time.
– From the drop-down menu, select the type of reboot:
* No Reboot (Manually Reboot System)
* Graceful Shutdown
* Force Shutdown
* Power Cycle System (cold boot)
NOTE: For PERC 8 or earlier controllers, Graceful Shutdown is the default option. For PERC 9 controllers,
No Reboot (Manually Reboot System) is the default option.
•
Add to Pending Operations
— Select this option to create a pending operation to apply the settings. You can view all
pending operations for a controller in the
Overview
→
Storage
→
Pending Operations
page.
219
Содержание iDRAC 7
Страница 1: ...iDRAC 8 7 v2 40 40 40 User s Guide ...
Страница 108: ...For more information see the iDRAC RACADM Command Line Interface Reference Guide available at dell com idracmanuals 108 ...
Страница 268: ...By default the logs are available at Event viewer Applications and Services Logs System 268 ...