* Configure controller properties.
* Import or auto-import foreign configuration.
* Clear foreign configuration.
* Reset controller configuration.
* Create or change security keys.
– PCIe SSD devices:
* Inventory and remotely monitor the health of PCIe SSD devices in the server.
* Prepare the PCIe SSD to be removed.
* Securely erase the data.
– Set the backplane mode (unified or split mode).
– Blink or unblink component LEDs.
– Apply the device settings immediately, at next system reboot, at a scheduled time, or as a pending operation to be applied as
a batch as part of the single job.
Update
•
Manage iDRAC licenses.
•
Update BIOS and device firmware for devices supported by Lifecycle Controller.
•
Update or rollback iDRAC firmware and Lifecycle Controller firmware using a single firmware image.
•
Manage staged updates.
•
Back up and restore server profile.
•
Access iDRAC interface over direct USB connection.
•
Configure iDRAC using Server Configuration Profiles on USB device.
Maintenance and Troubleshooting
•
Perform power-related operations and monitor power consumption.
•
Optimize system performance and power consumption by modifying the thermal settings.
•
No dependency on OpenManage Server Administrator for generation of alerts.
•
Log event data: Lifecycle and RAC logs.
•
Set email alerts, IPMI alerts, remote system logs, WS Eventing logs, Redfish event, and SNMP traps (v1, v2c, and v3) for events
and improved email alert notification.
•
Capture last system crash image.
•
View boot and crash capture videos.
•
Out-of-band monitor and alert the performance index of CPU, memory, and I/O modules.
•
Configure warning threshold for inlet temperature and power consumption.
•
Use iDRAC Service Module to:
– View operating system information.
– Replicate Lifecycle Controller logs to operating system logs.
– Automatic system recovery options.
– Remotely hard-reset iDRAC
– Enable in-band iDRAC SNMP alerts
– Access iDRAC using host OS (experimental feature)
– Populate Windows Management Instrumentation (WMI) information.
– Integrate with SupportAssist collection. This is applicable only if iDRAC Service Module Version 2.0 or later is installed. For
Generating SupportAssist Collection
.
– Prepare to remove NVMe PCIe SSD. For more information, see
.
•
Generate SupportAssist collection in the following ways:
– Automatic — Using iDRAC Service Module that automatically invokes the OS Collector tool.