11.3 Is It Connected Properly?
11.3 Is It Connected Properly?
Table 11–2 lists some problems that new users may have, and some problems
that may occur after new hardware has been installed. Many of these problems
can be solved easily by following the suggestions in the table. If these solutions
do not resolve the problem, see Section 11.4.
Table 11–2 Solutions to Common Problems
Problem
Solution
Amount of memory in
the cnfg 3 display is
incorrect.
1.
Note the slot location and size of each memory module listed in
the cnfg 3 display and compare it to the actual memory module
in the specified system unit memory slot. Reinstall any memory
modules that do not appear in the display (see Chapter 9).
2.
If the problem persists, type
t 3/mem *
at the console prompt and
see Section 11.5 to interpret the test results.
The NVRAM module
you ordered does not
appear in the cnfg 3
display.
1.
Turn off your workstation.
2.
Check to make sure that the NVRAM module is installed in
memory slot 14.
3.
Reinstall the NVRAM module (see Chapter 9).
4.
Turn on your workstation and try the cnfg 3 command again.
The status of the
NVRAM module in
the cnfg 3 display is
not
clean, batt OK,
armed
.
See the NVRAM chapter in the
TURBOchannel Options User’s Guide
for an explanation.
(continued on next page)
11–6 Troubleshooting
Содержание 5000/260
Страница 1: ...Order Number EK 4MMAX OP A01 DECstation 5000 Model 260 Operator s Guide...
Страница 14: ...Part I Introducing Your Workstation...
Страница 64: ...Part II External Additions to Your Workstation...
Страница 113: ...Part III Internal Parts and Additions to Your Workstation...
Страница 122: ...8 4 Using the Antistatic Wrist Strap Figure 8 3 Using an antistatic wrist strap MLO 010285 Inside the System Unit 8 9...
Страница 147: ...Part IV Managing Your Workstation...
Страница 192: ...Part V Appendixes...