6.5 Connecting the Workstation to an Ethernet Network
7. Push one of the connectors on the twisted-pair Ethernet cable into the
telephone-jack type of connector on the adapter until it clicks into place.
Figure 6–12 Connecting the twisted-pair cable to the twisted-pair adapter
WS3PO076
ThickWire-to-
twisted-pair adapter
Hold the telephone-jack
type of connector so the
clip is on the bottom.
To the ThickWire Ethernet
connector on system unit
8. Put Ethernet loopback connectors on any unused Ethernet connectors in
the TURBOchannel option slots (see Figure 6–1).
9. Contact your system manager or, if authorized to do so, follow your in-
house procedures to finish connecting the workstation to the twisted-pair
network when the network is not active. Your workstation will not operate
properly with an unterminated twisted-pair adapter until it is connected to
the network.