CTI 2500 Installation and Operation Guide V2.8
17
1.16 Ethernet Port
The Ethernet port allows you to connect the controller directly to an Ethernet network using a
standard RJ-45 connector. The port automatically selects between 10bT and 100bTX Ethernet
and between half or full duplex, depending on speed of the device to which it is connected. Two
status indicators that display Ethernet traffic are embedded into the connector.
TX- Transmit
Flashes when the port transmits an Ethernet packet.
RX- Receive
Flashes when the port receives an Ethernet packet. *
*Ethernet packets received by the port do not necessarily contain data for the controller.
See Section 7.4 for information regarding use of the Ethernet port.
1.17 RS-232/ RS-422 Serial Port
The serial port can support either an RS-232 or an RS-422 electrical interface. When the RS-
232 electrical interface is selected, you can connect to the RS-232 serial port on your PC using
a standard null modem cable or cables that are currently used with the Siemens Series 505
®
controllers. For longer cable runs, you can select the RS-422 electrical interface, which is
supported by some operator interface equipment.
The electrical interface and port baud rate via a set of user switches on the controller circuit
board. See Section 2.3 for further information regarding the user switches. The other port
parameters have constant values: Parity = Odd, Data Bits = 7, and Stop Bits = 1.
Normally, the serial port is used for programming and data access. However, you can change
the function of the port to a printer port (output only) by repositioning a jumper on the printed
circuit board (see Section 2.4). You can then use the PRINT statement to send a character
string to the printer our output device. See the
CTI 2500 Series Programming Reference Manua
l
for additional information.
If your application requires a custom cable, see APPENDIX F. – PRODUCT SPECIFICATIONS
for the port pinout.
1.18 Profibus-DP Port
This port allows you to connect the controller to a standard Profibus-DP network. See
CHAPTER 4 for more information on using Profibus and APPENDIX F. – PRODUCT
SPECIFICATIONS for the port pinout.
1.19 I/O Port
The I/O port enables you to connect CTI 2500 Series and SIMATIC Series 505
®
Remote I/O.
See CHAPTER 4 for additional information regarding remote I/O support and APPENDIX F. –
PRODUCT SPECIFICATIONS for the port pinout.
Содержание 2500-C100
Страница 1: ...CTI 2500 Series Controller INSTALLATION AND OPERATION GUIDE Version 2 8 CTI Part 062 00370 2500IOG...
Страница 10: ......
Страница 30: ......
Страница 34: ......
Страница 42: ......
Страница 50: ......
Страница 56: ......
Страница 62: ......
Страница 84: ......
Страница 102: ......
Страница 106: ......
Страница 110: ......