Fabric OS Administrator’s Guide
49
53-1001763-02
Enabling and disabling blades
3
FA4-18 application blade enabling exceptions
The Brocade 48000 director supports up to two FA4-18 blades in a chassis. The Brocade DCX and
DCX-4S Backbones support up to four FA4-18 blades in a chassis.
FC4-48 and FC8-48 port blade enabling exceptions
Because the area IDs are shared with different port IDs, the FC4-48 and FC8-48 blades support
only F_ and E_Ports. They do not support FL_Ports.
Port swapping on an FC4-48 or FC8-48 is supported only on ports 0–15. For the FC8-32 port blade,
port swapping is supported on all 32 ports. This means that if you replace a 32-port blade where a
port has been swapped on ports 16–31 with a 48-port blade, the 48-port blade faults. To correct
this, reinsert the 32-port blade and issue portSwap
to restore the original area IDs to ports 16–31.
FR4-18i application blade enabling exceptions
Note the following exceptions to enabling the FR4-18i application blade:
•
You have inserted the FR4-18i blade into a slot that was previously empty or contained an
FA4-18, FC4-16IP, FC4-48, FC8-16, FC8-32, FC8-48, FC10-6, FS8-18.
If the FR4-18i blade is operational and the platform is rebooted, then after the successful
bootup of the system the blade continues operations using the previous configurations.
If a previously configured FR4-18i blade is removed and another or the same FR4-18i blade is
inserted into the same slot, then the ports use the previous configuration and come up
enabled. If you do not want to use the previous configuration, you must clear the configuration
information, remove the blade, and then reseat the blade.
If a previously-configured FR4-18i blade is removed and an FC4-48, FC8-16, FC8-32, FC8-48,
or FC10-6 blade is plugged in, then—other than the port’s EX_Port configuration—all the
remaining port configurations previously applied to the FR4-18i ports can be used. The
EX_Port configuration on those ports is disabled before the FC4 or FC8 port blade becomes
operational. When a blade is present in the slot, then any requested port configuration is
validated against the blade’s capabilities before accepting the request. Also, hot swapping
causes the ports on the FR4-18i to be persistently disabled which later need to be enabled.
NOTE
The FC4-16IP blade is not supported in either the Brocade DCX or DCX-4S enterprise-class
platform.
•
You have turned on the power to the chassis and the FR4-18i blade in that slot was not active
prior to the power-on you must persistently enable the ports manually. For instructions on how
to manually persistently enable a port, refer to
“Port activation and deactivation”
on page 42.
ATTENTION
The ports of an FR4-18i are persistently disabled only if an FR4-18i was not previously in that
slot. You can replace an FR4-18i with another one with no change in the port states.
To summarize:
•
When an FC4-16, FC4-32, FC8-16, FC8-32, FC10-6, FC4-16IP, FA4-18, FS8-18, or FX8-24 blade
is replaced by an FR4-18i blade, the current port configuration continues to be used, and all
ports on the FR4-18i blade are persistently disabled.
Содержание 53-1001763-02
Страница 1: ...53 1001763 02 13 September 2010 Fabric OS Administrator s Guide Supporting Fabric OS v6 4 0 ...
Страница 4: ...iv Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 24: ...xxiv Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 28: ...xxviii Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 32: ...xxxii Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 40: ...xl Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 42: ...2 Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 54: ...14 Fabric OS Administrator s Guide 53 1001763 02 High availability of daemon processes 1 ...
Страница 74: ...34 Fabric OS Administrator s Guide 53 1001763 02 Basic connections 2 ...
Страница 102: ...62 Fabric OS Administrator s Guide 53 1001763 02 Audit log configuration 3 ...
Страница 156: ...116 Fabric OS Administrator s Guide 53 1001763 02 The authentication model using RADIUS and LDAP 5 ...
Страница 214: ...174 Fabric OS Administrator s Guide 53 1001763 02 Management interface security 7 ...
Страница 228: ...188 Fabric OS Administrator s Guide 53 1001763 02 Brocade configuration form 8 ...
Страница 276: ...236 Fabric OS Administrator s Guide 53 1001763 02 Creating a logical fabric using XISLs 10 ...
Страница 404: ...364 Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 440: ...400 Fabric OS Administrator s Guide 53 1001763 02 Performance data collection 17 ...
Страница 464: ...424 Fabric OS Administrator s Guide 53 1001763 02 Disabling bottleneck detection on a switch 18 ...
Страница 480: ...440 Fabric OS Administrator s Guide 53 1001763 02 F_Port masterless trunking 19 ...
Страница 494: ...454 Fabric OS Administrator s Guide 53 1001763 02 Buffer credit recovery 20 ...
Страница 560: ...520 Fabric OS Administrator s Guide 53 1001763 02 Port indexing on the Brocade DCX 4S backbone C ...
Страница 574: ...534 Fabric OS Administrator s Guide 53 1001763 02 Hexadecimal overview E ...