Creating a TI zone
12
Be aware of the ramifications if you create a TI zone with failover mode disabled. See
“TI zone
failover”
on page 268 for information about disabling failover mode.
3. Enter the cfgEnable command to reactivate your current effective configuration and enforce
the TI zones.
cfgenable "
current_effective_configuration
"
Example of creating a TI zone
The following examples create a TI zone named “bluezone”, which contains E_Ports 1,1 and 2,4
and N_Ports 1,8 and 2,6.
To create a TI zone with failover enabled and in the activated state (default settings):
switch:admin>
zone --create -t ti bluezone -p "1,1; 2,4; 1,8; 2,6"
To create a TI zone with failover enabled (the zone is set to the activated state by default):
switch:admin>
zone --create -t ti -o f bluezone -p "1,1; 2,4; 1,8; 2,6"
To create a TI zone with failover disabled and the state set to activated:
switch:admin>
zone --create -t ti -o an bluezone -p "1,1; 2,4; 1,8; 2,6"
To create a TI zone and set the state to deactivated (failover is enabled by default):
switch:admin>
zone --create -t ti -o d bluezone -p "1,1; 2,4; 1,8; 2,6"
To create a TI zone with failover disabled and the state set to deactivated:
switch:admin>
zone --create -t ti -o dn bluezone -p "1,1; 2,4; 1,8; 2,6"
To create a TI zone in the edge fabric with failover enabled and the state set to activated (default
settings):
switch:admin>
zone --create -t ti bluezone -p "1,1; 1,8; 2,-1; 3,-1"
To create a TI zone in the backbone fabric with failover enabled and the state set to activated
(default settings):
switch:admin>
zone --create -t ti backbonezone -p "10:00:00:04:1f:03:16:f2;
1,1; 1,4; 2,7; 2,1; 10:00:00:04:1f:03:18:f1, 10:00:00:04:1f:04:06:e2"
To create TI zones in a logical fabric, such as the one shown in
Figure 45
on page 280:
Log in to the logical switch FID1, Domain 7 and create a TI zone in the logical fabric with FID=1:
LS1> zone --create -t ti -o f "ti_zone1" -p "8,8; 8,1; 3,3; 3,10; 5,16; 5,8;
9,5; 9,9"
Then create a TI zone in the base fabric, as described in
“Creating a TI zone in a base fabric”
.
Remember that your changes are not enforced until you enter the cfgEnable command, as shown
here:
switch:admin>
cfgenable "USA_cfg"
You are about to enable a new zoning configuration.
This action will replace the old zoning configuration with the
current configuration selected.
If the update includes changes to one or more traffic isolation zones, the
update may result in localized disruption to traffic on ports associated with
the traffic isolation zone changes
Do you want to enable 'USA_cfg' configuration (yes, y, no, n): [no]
y
zone config "USA_cfg" is in effect
Updating flash ...
Содержание 53-1001763-02
Страница 1: ...53 1001763 02 13 September 2010 Fabric OS Administrator s Guide Supporting Fabric OS v6 4 0 ...
Страница 4: ...iv Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 24: ...xxiv Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 28: ...xxviii Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 32: ...xxxii Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 40: ...xl Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 42: ...2 Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 54: ...14 Fabric OS Administrator s Guide 53 1001763 02 High availability of daemon processes 1 ...
Страница 74: ...34 Fabric OS Administrator s Guide 53 1001763 02 Basic connections 2 ...
Страница 102: ...62 Fabric OS Administrator s Guide 53 1001763 02 Audit log configuration 3 ...
Страница 156: ...116 Fabric OS Administrator s Guide 53 1001763 02 The authentication model using RADIUS and LDAP 5 ...
Страница 214: ...174 Fabric OS Administrator s Guide 53 1001763 02 Management interface security 7 ...
Страница 228: ...188 Fabric OS Administrator s Guide 53 1001763 02 Brocade configuration form 8 ...
Страница 276: ...236 Fabric OS Administrator s Guide 53 1001763 02 Creating a logical fabric using XISLs 10 ...
Страница 404: ...364 Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 440: ...400 Fabric OS Administrator s Guide 53 1001763 02 Performance data collection 17 ...
Страница 464: ...424 Fabric OS Administrator s Guide 53 1001763 02 Disabling bottleneck detection on a switch 18 ...
Страница 480: ...440 Fabric OS Administrator s Guide 53 1001763 02 F_Port masterless trunking 19 ...
Страница 494: ...454 Fabric OS Administrator s Guide 53 1001763 02 Buffer credit recovery 20 ...
Страница 560: ...520 Fabric OS Administrator s Guide 53 1001763 02 Port indexing on the Brocade DCX 4S backbone C ...
Страница 574: ...534 Fabric OS Administrator s Guide 53 1001763 02 Hexadecimal overview E ...