Fabric OS Administrator’s Guide
53-1001763-02
IP address and routing management
B
Deleting an Inband Management route
1. Connect to the switch and log in as admin.
2. Enter the portCfg inbandmgmt command to delete a route to the Management Station.
switch:admin> portcfg inbandmgmt ge0 routedel 192.168.3.0 255.255.255.0
Viewing Inband Management IP addresses and routes
The portShow inbandmgmt command displays the addresses that are currently configured for that
GE port number and a status of Inband Management (Enabled/Disabled). To display the routing
table, use the existing portShow iproute command. There is a status flag for the IP routes to signify
if a route is used for the management interfaces. After the route definition is printed, a
Management option appears at the end of the line. This indicates that the route is using one of the
internal interfaces.
The portCfgShow inbandmgmt command displays the addresses that are currently configured for
that GE port number. The portCfgShow command also displays any Inband Management routes
configured in the Iproute Configuration section.
To provide connection between the CP and the management station, IP routes must be added to all
Ethernet devices between the two. To make sure that only traffic destined for the management
interface on the CP is sent to the Brocade 7500 Extension Switches, it is recommended you use
host-specific routes for the Brocade 7500 management destination routes. This ensures that the
Brocade 7500 Extension Switch is not acting as a full IP router between the various subnets. To
ensure proper connectivity, routes must be added to each hop along the desired path.
Viewing Inband Management IP routes
1. Connect to the switch and log in as admin.
2. Enter the portShow iproute command specifying the GE port you want to view.
The portShow command has additional information displayed in the iproute display option. The
routes display the Management designation if they are routes associated with the CP-to-GE
connectivity as shown below:
switch:admin> portshow iproute ge1
Port: ge1
IP Address Mask Gateway Metric
-----------------------------------------------------
192.168.112.0 255.255.255.0 192.168.112.61 0 Interface
192.168.255.0 255.255.255.0 192.168.255.2 0 Interface Management
10.1.1.61 255.255.255.255 192.168.255.1 0 Management
192.168.102.0 255.255.255.0 192.168.112.1 0
192.168.106.0 255.255.255.0 192.168.112.1 0
192.168.255.0 255.255.255.0 192.168.255.1 0 Interface Management
192.168.112.60 255.255.255.255 192.168.255.2 0 Management
IPv6 Address Len Gateway Metric
---------------------------------------------------------------------------------
In this example, the interface on the GE port processor is set up with an address of
192.168.255.2/24 and the address on inbd0 on the CP is set up with the address
192.168.255.1/24. There is an “Interface Management” route on the GE port processor for
192.168.255.0/24 with a gateway 192.168.255.2 and an “Interface Management” route on the
Содержание 53-1001763-02
Страница 1: ...53 1001763 02 13 September 2010 Fabric OS Administrator s Guide Supporting Fabric OS v6 4 0 ...
Страница 4: ...iv Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 24: ...xxiv Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 28: ...xxviii Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 32: ...xxxii Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 40: ...xl Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 42: ...2 Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 54: ...14 Fabric OS Administrator s Guide 53 1001763 02 High availability of daemon processes 1 ...
Страница 74: ...34 Fabric OS Administrator s Guide 53 1001763 02 Basic connections 2 ...
Страница 102: ...62 Fabric OS Administrator s Guide 53 1001763 02 Audit log configuration 3 ...
Страница 156: ...116 Fabric OS Administrator s Guide 53 1001763 02 The authentication model using RADIUS and LDAP 5 ...
Страница 214: ...174 Fabric OS Administrator s Guide 53 1001763 02 Management interface security 7 ...
Страница 228: ...188 Fabric OS Administrator s Guide 53 1001763 02 Brocade configuration form 8 ...
Страница 276: ...236 Fabric OS Administrator s Guide 53 1001763 02 Creating a logical fabric using XISLs 10 ...
Страница 404: ...364 Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 440: ...400 Fabric OS Administrator s Guide 53 1001763 02 Performance data collection 17 ...
Страница 464: ...424 Fabric OS Administrator s Guide 53 1001763 02 Disabling bottleneck detection on a switch 18 ...
Страница 480: ...440 Fabric OS Administrator s Guide 53 1001763 02 F_Port masterless trunking 19 ...
Страница 494: ...454 Fabric OS Administrator s Guide 53 1001763 02 Buffer credit recovery 20 ...
Страница 560: ...520 Fabric OS Administrator s Guide 53 1001763 02 Port indexing on the Brocade DCX 4S backbone C ...
Страница 574: ...534 Fabric OS Administrator s Guide 53 1001763 02 Hexadecimal overview E ...