Fabric OS Administrator’s Guide
421
53-1001763-02
Changing bottleneck alert parameters
18
The alert parameters include whether alerts are sent and the threshold, time, and quiet time
options.
For a trunk, you can change the alert parameters only on the master port only.
1. Connect to the switch and log in as admin.
2. Enter the bottleneckmon
--
config command to set the alert option and specify new threshold
values.
Enter the bottleneckmon
--
configclear command to remove any port-specific alert parameters
and revert to the switch-wide parameters.
Example
The following example disables alerts on port 1, excludes ports 2, 3, and 4 from bottleneck
monitoring, and changes the alert settings on ports 2 and 3. The bottleneck
--
status command
shows the settings for these ports. Note that this example changes the alert settings on ports 2
and 3, even though they are excluded from bottleneck detection.
switch:admin>
bottleneckmon --config -noalert 1
switch:admin>
bottleneckmon --exclude 2-4
switch:admin>
bottleneckmon --config -alert -lthresh .99 -cthresh .9 -time
4000 -qtime 600 2-3
switch:admin>
bottleneckmon --status
Bottleneck detection - Enabled
==============================
Switch-wide alerting parameters:
============================
Alerts - Yes
Latency threshold for alert - 0.100
Congestion threshold for alert - 0.800
Averaging time for alert - 300 seconds
Quiet time for alert - 300 seconds
Per-port overrides for alert parameters:
========================================
Slot Port Alerts? LatencyThresh CongestionThresh Time(s) QTime(s)
=======================================================================
0 1 N
--
--
--
--
0 2 Y 0.990 0.900 4000 600
0 3 Y 0.990 0.900 4000 600
Excluded ports:
===============
Port
====
2
3
4
Example
The following example changes alert settings for the entire logical switch.
switch:admin>
bottleneckmon --config -alert -lthresh .97 -cthresh .8 -time
5000
switch:admin>
bottleneckmon --status
Bottleneck detection - Enabled
==============================
Содержание 53-1001763-02
Страница 1: ...53 1001763 02 13 September 2010 Fabric OS Administrator s Guide Supporting Fabric OS v6 4 0 ...
Страница 4: ...iv Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 24: ...xxiv Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 28: ...xxviii Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 32: ...xxxii Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 40: ...xl Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 42: ...2 Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 54: ...14 Fabric OS Administrator s Guide 53 1001763 02 High availability of daemon processes 1 ...
Страница 74: ...34 Fabric OS Administrator s Guide 53 1001763 02 Basic connections 2 ...
Страница 102: ...62 Fabric OS Administrator s Guide 53 1001763 02 Audit log configuration 3 ...
Страница 156: ...116 Fabric OS Administrator s Guide 53 1001763 02 The authentication model using RADIUS and LDAP 5 ...
Страница 214: ...174 Fabric OS Administrator s Guide 53 1001763 02 Management interface security 7 ...
Страница 228: ...188 Fabric OS Administrator s Guide 53 1001763 02 Brocade configuration form 8 ...
Страница 276: ...236 Fabric OS Administrator s Guide 53 1001763 02 Creating a logical fabric using XISLs 10 ...
Страница 404: ...364 Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 440: ...400 Fabric OS Administrator s Guide 53 1001763 02 Performance data collection 17 ...
Страница 464: ...424 Fabric OS Administrator s Guide 53 1001763 02 Disabling bottleneck detection on a switch 18 ...
Страница 480: ...440 Fabric OS Administrator s Guide 53 1001763 02 F_Port masterless trunking 19 ...
Страница 494: ...454 Fabric OS Administrator s Guide 53 1001763 02 Buffer credit recovery 20 ...
Страница 560: ...520 Fabric OS Administrator s Guide 53 1001763 02 Port indexing on the Brocade DCX 4S backbone C ...
Страница 574: ...534 Fabric OS Administrator s Guide 53 1001763 02 Hexadecimal overview E ...