496
Fabric OS Administrator’s Guide
53-1001763-02
Displaying the range of output ports connected to xlate domains
21
If you replace an 8-Gbps port blade or FX8-24 blade with an FR4-18i blade, the EX_Port
configuration remains the same for all ports on the FR4-18i blade. All ports are persistently
disabled.
If you replace an 8-Gbps port blade with an FX8-24 blade, the EX_Port configuration remains the
same for the first 12 FC ports on the FX8-24 blade.
If you replace an 8-Gbps port blade or FX8-24 blade with another 8-Gbps port blade, the EX_Port
configuration remains the same.
Displaying the range of output ports connected to xlate domains
The edge fabric detects only one front domain from an FC router connected through multiple output
ports. The output port of the front domain is not fixed to 0; the values can be in a range of 129–
255. The range of the output ports connected to the xlate domain is 1–128. This range enables the
front domain to connect to 127 remote xlate domains.
1. Log in to a switch in the edge fabric.
2. Enter the lsDbShow command on the edge fabric.
In the lsDbShow output, ports in the range of 129–255 are the output ports on the front
domain.
The following example shows the range of output ports.
linkCnt = 2, flags = 0x0
LinkId = 53, out port = 1, rem port = 35, cost = 500, costCnt = 0, type = 1
LinkId = 57,
out port = 129
, rem port = 18, cost = 500, costCnt = 0, type = 1
The following example also shows the use of the lsDbShow display on the edge fabric. The front
domain, domain 3, has two links representing two EX_Port connections with output ports 129
and 132.
Domain = 3, Link State Database Entry pointer = 0x100bbcc0
………
linkCnt = 4, flags = 0x0
LinkId = 199,
out port = 129
, rem port = 2, cost = 10000, costCnt = 0, type = 1
LinkId = 199,
out port = 132
, rem port = 3, cost = 10000, costCnt = 0, type = 1
LinkId = 2, out port = 1, rem port = 2, cost = 10000, costCnt = 0, type = 1
LinkId = 1, out port = 32, rem port = 2, cost = 10000, costCnt = 0, type = 1
Содержание 53-1001763-02
Страница 1: ...53 1001763 02 13 September 2010 Fabric OS Administrator s Guide Supporting Fabric OS v6 4 0 ...
Страница 4: ...iv Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 24: ...xxiv Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 28: ...xxviii Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 32: ...xxxii Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 40: ...xl Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 42: ...2 Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 54: ...14 Fabric OS Administrator s Guide 53 1001763 02 High availability of daemon processes 1 ...
Страница 74: ...34 Fabric OS Administrator s Guide 53 1001763 02 Basic connections 2 ...
Страница 102: ...62 Fabric OS Administrator s Guide 53 1001763 02 Audit log configuration 3 ...
Страница 156: ...116 Fabric OS Administrator s Guide 53 1001763 02 The authentication model using RADIUS and LDAP 5 ...
Страница 214: ...174 Fabric OS Administrator s Guide 53 1001763 02 Management interface security 7 ...
Страница 228: ...188 Fabric OS Administrator s Guide 53 1001763 02 Brocade configuration form 8 ...
Страница 276: ...236 Fabric OS Administrator s Guide 53 1001763 02 Creating a logical fabric using XISLs 10 ...
Страница 404: ...364 Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 440: ...400 Fabric OS Administrator s Guide 53 1001763 02 Performance data collection 17 ...
Страница 464: ...424 Fabric OS Administrator s Guide 53 1001763 02 Disabling bottleneck detection on a switch 18 ...
Страница 480: ...440 Fabric OS Administrator s Guide 53 1001763 02 F_Port masterless trunking 19 ...
Страница 494: ...454 Fabric OS Administrator s Guide 53 1001763 02 Buffer credit recovery 20 ...
Страница 560: ...520 Fabric OS Administrator s Guide 53 1001763 02 Port indexing on the Brocade DCX 4S backbone C ...
Страница 574: ...534 Fabric OS Administrator s Guide 53 1001763 02 Hexadecimal overview E ...