Fabric OS Administrator’s Guide
53-1001763-02
E_Port authentication between Fabric OS and M-EOS switches
14
Authentication policy when the secrets are not correct
Table 61
and
Table 62
show the connection status for the cases where the authentication secrets
are incorrect.
Table 61
shows the E_Port connection status when the Fabric OS switch does not
have the correct secret for the M-EOS switch.
In this case, when the Fabric OS switch is in Active or On mode, and the M-EOS switch is Off, the
E_Port does not connect because the Fabric OS switch rejects the authentication based on the
secret mismatch. However,
Table 62
shows the opposite case where the M-EOS switch has the
incorrect peer secret for the Fabric OS switch. In the same condition, when the Fabric OS switch is
in Active or On mode, and the M-EOS is Off, the E_Port does connect (one-way authentication)
because the M-EOS will not perform authentication. The fact that the secret is wrong is
insignificant.
TABLE 61
Switch authentication policy - Fabric OS switch with incorrect peer secret for M-EOS switch
Fabric OS
Passive
Active
On
Off
M-EOS
On
No
E_Port does not
connect
(Authentication
Rejected). When the
Fabric OS switch
generates the reject,
it will disable the
Fabric OS port. When
the M-EOS switch
generates the reject,
it will go to an invalid
attachment state.
No
E_Port does not connect
(Authentication
Rejected). When the
Fabric OS switch
generates the reject, it
will disable the Fabric OS
port. When the M-EOS
switch generates the
reject, it will go to an
invalid attachment state.
No
E_Port does not connect
(Authentication
Rejected). When the
Fabric OS switch
generates the reject, it
will disable the Fabric OS
port. When the M-EOS
switch generates the
reject, it will go to an
invalid attachment state.
No
E_Port does not
connect
(Authentication
Rejected). When the
Fabric OS switch
generates the reject, it
will disable the Fabric
OS port. When the
M-EOS switch
generates the reject, it
will go to an invalid
attachment state.
Off
Yes
Connected without
any authentication
(Fabric builds
normally).
No
E_Port does not connect
(Authentication
Rejected). When the
Fabric OS switch
generates the reject, it
will disable the Fabric OS
port. When the M-EOS
switch generates the
reject, it will go to an
invalid attachment state.
No
E_Port does not connect
(Authentication
Rejected). When the
Fabric OS switch
generates the reject, it
will disable the Fabric OS
port. When the M-EOS
switch generates the
reject, it will go to an
invalid attachment state.
Yes
Connected without any
authentication (Fabric
builds normally).
Содержание 53-1001763-02
Страница 1: ...53 1001763 02 13 September 2010 Fabric OS Administrator s Guide Supporting Fabric OS v6 4 0 ...
Страница 4: ...iv Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 24: ...xxiv Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 28: ...xxviii Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 32: ...xxxii Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 40: ...xl Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 42: ...2 Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 54: ...14 Fabric OS Administrator s Guide 53 1001763 02 High availability of daemon processes 1 ...
Страница 74: ...34 Fabric OS Administrator s Guide 53 1001763 02 Basic connections 2 ...
Страница 102: ...62 Fabric OS Administrator s Guide 53 1001763 02 Audit log configuration 3 ...
Страница 156: ...116 Fabric OS Administrator s Guide 53 1001763 02 The authentication model using RADIUS and LDAP 5 ...
Страница 214: ...174 Fabric OS Administrator s Guide 53 1001763 02 Management interface security 7 ...
Страница 228: ...188 Fabric OS Administrator s Guide 53 1001763 02 Brocade configuration form 8 ...
Страница 276: ...236 Fabric OS Administrator s Guide 53 1001763 02 Creating a logical fabric using XISLs 10 ...
Страница 404: ...364 Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 440: ...400 Fabric OS Administrator s Guide 53 1001763 02 Performance data collection 17 ...
Страница 464: ...424 Fabric OS Administrator s Guide 53 1001763 02 Disabling bottleneck detection on a switch 18 ...
Страница 480: ...440 Fabric OS Administrator s Guide 53 1001763 02 F_Port masterless trunking 19 ...
Страница 494: ...454 Fabric OS Administrator s Guide 53 1001763 02 Buffer credit recovery 20 ...
Страница 560: ...520 Fabric OS Administrator s Guide 53 1001763 02 Port indexing on the Brocade DCX 4S backbone C ...
Страница 574: ...534 Fabric OS Administrator s Guide 53 1001763 02 Hexadecimal overview E ...