Fabric OS Administrator’s Guide
53-1001763-02
Fabric configurations for interconnectivity
A
To allow interconnectivity with M-EOS SANs, use the -m option on the portCfgEXPort command to
indicate the connectivity mode.
Table 98
lists the valid parameters to use with the -m option to set
the connectivity mode.
You can display the current operational mode of the EX_Port by issuing the portCfgExPort
command with the port number as the only parameter.
The following command sequence is an example to connect port 5 to an M-EOS fabric in McDATA
Fabric Mode:
switch:admin>
portdisable 5
switch:admin>
portcfgexport 5 -m 2
switch:admin>
portenable 5
See
“Inter-fabric link configuration”
on page 468 for details about the portCfgExPort command,
which is used for McDATA Fabric mode on Fabric OS v5.2.0 or later.
Configuring the FC router
When configuring a Fabric OS fabric to connect to a Native McDATA fabric, you must perform some
preparation on the FC router. The following procedure shows how to connect an EX_Port of an FC
router to a Native McDATA fabric configured in Fabric mode.
NOTE
For additional information on configuring the FC router, refer to
Chapter 21, “Using the FC-FC Routing
Service”
.
1. To verify the Native McDATA firmware version, use the M-EOSc show system command.
2. To display the front domain on the M-EOS fabric, use the M-EOS showfabric topology
command.
3. Using the Fabric OS firmwareShow command, make sure that Fabric OS v6.4.0 or later is
installed on the FC router, as shown in the following example:
B7800_170:admin> firmwareshow
Appl Primary/Secondary Versions
------------------------------------------
FOS v6.4.0
v6.4.0
4. On the FC router, use the portDisable command to disable the EX_Port that you will use to
connect to the M-EOS switch. Ports are persistently disabled by default.
5. Enter the portCfgExPort command to configure the port as an EX_Port with a different FID
within the McDATA Fabric Mode.
This port can now connect to an M-EOS switch in McDATA Fabric mode or McDATA Open mode.
TABLE 98
portCfgEXPort -m values
Value
Description
Use
0
Brocade Native
Default mode.
1
McDATA Open Mode 1
When the neighboring M-EOS switch is running in open mode.
2
McDATA Fabric Mode (native mode)
When the neighboring M-EOS switch is running in native mode.
3
McData Fabric legacy mode
Not currently used.
Содержание 53-1001763-02
Страница 1: ...53 1001763 02 13 September 2010 Fabric OS Administrator s Guide Supporting Fabric OS v6 4 0 ...
Страница 4: ...iv Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 24: ...xxiv Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 28: ...xxviii Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 32: ...xxxii Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 40: ...xl Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 42: ...2 Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 54: ...14 Fabric OS Administrator s Guide 53 1001763 02 High availability of daemon processes 1 ...
Страница 74: ...34 Fabric OS Administrator s Guide 53 1001763 02 Basic connections 2 ...
Страница 102: ...62 Fabric OS Administrator s Guide 53 1001763 02 Audit log configuration 3 ...
Страница 156: ...116 Fabric OS Administrator s Guide 53 1001763 02 The authentication model using RADIUS and LDAP 5 ...
Страница 214: ...174 Fabric OS Administrator s Guide 53 1001763 02 Management interface security 7 ...
Страница 228: ...188 Fabric OS Administrator s Guide 53 1001763 02 Brocade configuration form 8 ...
Страница 276: ...236 Fabric OS Administrator s Guide 53 1001763 02 Creating a logical fabric using XISLs 10 ...
Страница 404: ...364 Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 440: ...400 Fabric OS Administrator s Guide 53 1001763 02 Performance data collection 17 ...
Страница 464: ...424 Fabric OS Administrator s Guide 53 1001763 02 Disabling bottleneck detection on a switch 18 ...
Страница 480: ...440 Fabric OS Administrator s Guide 53 1001763 02 F_Port masterless trunking 19 ...
Страница 494: ...454 Fabric OS Administrator s Guide 53 1001763 02 Buffer credit recovery 20 ...
Страница 560: ...520 Fabric OS Administrator s Guide 53 1001763 02 Port indexing on the Brocade DCX 4S backbone C ...
Страница 574: ...534 Fabric OS Administrator s Guide 53 1001763 02 Hexadecimal overview E ...