Fabric OS Administrator’s Guide
395
53-1001763-02
Top Talker monitors
17
1. Connect to the switch and log in as admin.
2. Remove any end-to-end monitors in the fabric, as described in
“Deleting end-to-end monitors”
on page 388. Fabric Mode Top Talker monitors and end-to-end monitors cannot both exist in
the fabric.
3. Enter the perfTTmon
--
add fabricmode command.
perfttmon --add fabricmode
The system responds:
Before enabling fabric mode, please remove all EE monitors in the fabric
continue? (yes, y, no, n):
4. Type y at the prompt to continue.
Top Talker monitors are added to E_Ports in the fabric and fabric mode is enabled. Any Top
Talker monitors that were already installed on F_Ports are automatically uninstalled.
If end-to-end monitors are present on the local switch, the command fails with the message:
Cannot install Fabric Mode Top Talker because EE monitor is already present
If end-to-end monitors are present on remote switches running Fabric OS 6.1.0 or later, the
command succeeds; however, on the remote switches, fabric mode fails and a raslog message
is displayed on those switches.
If end-to-end monitors are present on remote switches running Fabric OS 6.0.x, the command
succeeds.
If a new switch joins the fabric, you must run the perfTTmon --add fabricmode command on the
new switch. The Top Talker configuration information is
not
automatically propagated to the
new switch.
Displaying the top
n
bandwidth-using flows on an F_Port
1. Connect to the switch and log in as admin.
2. Enter the perfTTmon
--
show command.
perfttmon --show [
slotnumber
/]
port
[
n
] [wwn | pid]
The output is sorted based on the data rate of each flow. If you do not specify the number of
flows to display, then the command displays the top 8 flows or the total number of flows,
whichever is less.
For example, to display the top 5 flows on port 7 in WWN (default) format:
perfttmon --show 7 5
To display the top flows on slot 2, port 4 on the Brocade 48000, Brocade DCX, or DCX-4S in PID
format:
perfttmon --show 2/4 pid
switch:admin>
perfttmon --show 2/4 pid
========================================
Src_PID
Dst_PID
MB/sec
========================================
0xa90800
0xa05200
6.926
0xa90800
0xa908ef
6.872
Содержание 53-1001763-02
Страница 1: ...53 1001763 02 13 September 2010 Fabric OS Administrator s Guide Supporting Fabric OS v6 4 0 ...
Страница 4: ...iv Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 24: ...xxiv Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 28: ...xxviii Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 32: ...xxxii Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 40: ...xl Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 42: ...2 Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 54: ...14 Fabric OS Administrator s Guide 53 1001763 02 High availability of daemon processes 1 ...
Страница 74: ...34 Fabric OS Administrator s Guide 53 1001763 02 Basic connections 2 ...
Страница 102: ...62 Fabric OS Administrator s Guide 53 1001763 02 Audit log configuration 3 ...
Страница 156: ...116 Fabric OS Administrator s Guide 53 1001763 02 The authentication model using RADIUS and LDAP 5 ...
Страница 214: ...174 Fabric OS Administrator s Guide 53 1001763 02 Management interface security 7 ...
Страница 228: ...188 Fabric OS Administrator s Guide 53 1001763 02 Brocade configuration form 8 ...
Страница 276: ...236 Fabric OS Administrator s Guide 53 1001763 02 Creating a logical fabric using XISLs 10 ...
Страница 404: ...364 Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 440: ...400 Fabric OS Administrator s Guide 53 1001763 02 Performance data collection 17 ...
Страница 464: ...424 Fabric OS Administrator s Guide 53 1001763 02 Disabling bottleneck detection on a switch 18 ...
Страница 480: ...440 Fabric OS Administrator s Guide 53 1001763 02 F_Port masterless trunking 19 ...
Страница 494: ...454 Fabric OS Administrator s Guide 53 1001763 02 Buffer credit recovery 20 ...
Страница 560: ...520 Fabric OS Administrator s Guide 53 1001763 02 Port indexing on the Brocade DCX 4S backbone C ...
Страница 574: ...534 Fabric OS Administrator s Guide 53 1001763 02 Hexadecimal overview E ...