492
Fabric OS Administrator’s Guide
53-1001763-02
FC-FC Routing and Virtual Fabrics
21
LSAN Devices:
10000
51
Proxy Device Slots:
10000
20
WWN Pool Size
Allocated
---------------------------------
Phantom Node WWN:
8192
5413
Phantom Port WWN:
32768
16121
Port Limits:
Max proxy devices:
2000
Max NR_Ports:
1000
Currently Used(column 1: proxy, column 2: NR_Ports):
0 |
0
34
1 |
3
34
4 |
0
0
5 |
0
0
6 |
0
0
7 |
0
0
8 |
6
34
9 |
6
34
10 |
6
34
11 |
6
34
12 |
6
34
13 |
6
34
14 |
6
34
15 |
6
34
16 |
8
34
17 |
8
34
18 |
8
34
19 |
8
34
20 |
8
34
21 |
8
34
22 |
8
34
23 |
8
34
FC-FC Routing and Virtual Fabrics
If Virtual Fabrics is not enabled, FC-FC routing behavior is unchanged. If Virtual Fabrics is enabled,
then in the FC-FC routing context, a base switch is like a backbone switch and a base fabric is like a
backbone fabric.
If Virtual Fabrics is enabled, the following rules apply:
•
EX_Ports and VEX_Ports can be configured only on the base switch.
When you enable Virtual Fabrics, the chassis is automatically rebooted. When the switch
comes up, only one default logical switch is present, with the default fabric ID (FID) of 128. All
previously configured EX_Ports and VEX_Ports are persistently disabled with the reason
“ExPort in non base switch”. You must explicitly create a base switch, move the EX_ and
VEX_Ports to the base switch, and then enable the ports.
If you move existing EX_ or VEX_Ports to any logical switch other than the base switch, these
ports are automatically disabled.
If you want to change an EX_ or VEX_Port on the logical switch to be a non-EX or VEX_Port, you
must use the portCfgDefault command. You cannot use the portCfgExPort command because
that command is allowed only on the base switch.
Содержание 53-1001763-02
Страница 1: ...53 1001763 02 13 September 2010 Fabric OS Administrator s Guide Supporting Fabric OS v6 4 0 ...
Страница 4: ...iv Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 24: ...xxiv Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 28: ...xxviii Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 32: ...xxxii Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 40: ...xl Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 42: ...2 Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 54: ...14 Fabric OS Administrator s Guide 53 1001763 02 High availability of daemon processes 1 ...
Страница 74: ...34 Fabric OS Administrator s Guide 53 1001763 02 Basic connections 2 ...
Страница 102: ...62 Fabric OS Administrator s Guide 53 1001763 02 Audit log configuration 3 ...
Страница 156: ...116 Fabric OS Administrator s Guide 53 1001763 02 The authentication model using RADIUS and LDAP 5 ...
Страница 214: ...174 Fabric OS Administrator s Guide 53 1001763 02 Management interface security 7 ...
Страница 228: ...188 Fabric OS Administrator s Guide 53 1001763 02 Brocade configuration form 8 ...
Страница 276: ...236 Fabric OS Administrator s Guide 53 1001763 02 Creating a logical fabric using XISLs 10 ...
Страница 404: ...364 Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 440: ...400 Fabric OS Administrator s Guide 53 1001763 02 Performance data collection 17 ...
Страница 464: ...424 Fabric OS Administrator s Guide 53 1001763 02 Disabling bottleneck detection on a switch 18 ...
Страница 480: ...440 Fabric OS Administrator s Guide 53 1001763 02 F_Port masterless trunking 19 ...
Страница 494: ...454 Fabric OS Administrator s Guide 53 1001763 02 Buffer credit recovery 20 ...
Страница 560: ...520 Fabric OS Administrator s Guide 53 1001763 02 Port indexing on the Brocade DCX 4S backbone C ...
Страница 574: ...534 Fabric OS Administrator s Guide 53 1001763 02 Hexadecimal overview E ...