Fabric OS Administrator’s Guide
475
53-1001763-02
EX_Port frame trunking configuration
21
Table 94
lists the platforms that support FC-FC routing, indicates whether masterless EX_Port
frame trunking is supported and, if supported, whether Virtual Fabrics must be enabled or
disabled.
Supported configurations and platforms
The EX_Port trunking is an FCR software feature and requires that you have a trunking license
installed on the FC router and on the edge fabric connected to the other side of the trunked
EX_Ports. EX_Port trunking is supported only with Brocade edge fabrics. You can use EX_Port
frame trunking in the following configurations and cases:
•
For ports with speeds of 2 Gbps up to a maximum speed of 8 Gbps and trunking over long
distance.
•
In the edge fabric, when the FC router is connected to a switch that supports eight ports from
the trunkable group.
•
When the FC router is connected to an edge fabric using a mix of trunked and non-trunked
EX_Ports. All will share the same front domain.
•
In edge-to-edge, backbone-to-edge, and dual backbone configurations.
Masterless EX_Port trunking has additional configuration requirements. See
“Masterless EX_Port
trunking”
on page 474 for these additional requirements.
NOTE
QoS and EX_Port trunking can co-exist; however, if some ports in the trunk group have QoS enabled
and some have QoS disabled, then two trunk groups will form: one with QoS enabled and one with
QoS disabled.
TABLE 94
Supported platforms and VF mode for masterless EX_Port trunking
Supported platforms for FCR
Masterless EX_Port trunking supported? VF mode required for masterless EX_Port trunking
Brocade DCX and DCX-4S:
FC8-16
FC8-32
FC8-48
FC8-64
FS8-18
FX8-24
FR4-18i
yes
yes
yes
yes
yes
yes
no
enabled
enabled
enabled
enabled
enabled
enabled
n/a
Brocade 5100
yes
enabled or disabled
Brocade 5300
yes
enabled or disabled
Brocade VA-40FC
yes
enabled or disabled
Brocade Encryption Switch yes
enabled or disabled
Brocade 7500
no
n/a
Brocade 7800
no
n/a
Brocade 48000:
FR4-18i
no
n/a
Содержание 53-1001763-02
Страница 1: ...53 1001763 02 13 September 2010 Fabric OS Administrator s Guide Supporting Fabric OS v6 4 0 ...
Страница 4: ...iv Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 24: ...xxiv Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 28: ...xxviii Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 32: ...xxxii Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 40: ...xl Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 42: ...2 Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 54: ...14 Fabric OS Administrator s Guide 53 1001763 02 High availability of daemon processes 1 ...
Страница 74: ...34 Fabric OS Administrator s Guide 53 1001763 02 Basic connections 2 ...
Страница 102: ...62 Fabric OS Administrator s Guide 53 1001763 02 Audit log configuration 3 ...
Страница 156: ...116 Fabric OS Administrator s Guide 53 1001763 02 The authentication model using RADIUS and LDAP 5 ...
Страница 214: ...174 Fabric OS Administrator s Guide 53 1001763 02 Management interface security 7 ...
Страница 228: ...188 Fabric OS Administrator s Guide 53 1001763 02 Brocade configuration form 8 ...
Страница 276: ...236 Fabric OS Administrator s Guide 53 1001763 02 Creating a logical fabric using XISLs 10 ...
Страница 404: ...364 Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 440: ...400 Fabric OS Administrator s Guide 53 1001763 02 Performance data collection 17 ...
Страница 464: ...424 Fabric OS Administrator s Guide 53 1001763 02 Disabling bottleneck detection on a switch 18 ...
Страница 480: ...440 Fabric OS Administrator s Guide 53 1001763 02 F_Port masterless trunking 19 ...
Страница 494: ...454 Fabric OS Administrator s Guide 53 1001763 02 Buffer credit recovery 20 ...
Страница 560: ...520 Fabric OS Administrator s Guide 53 1001763 02 Port indexing on the Brocade DCX 4S backbone C ...
Страница 574: ...534 Fabric OS Administrator s Guide 53 1001763 02 Hexadecimal overview E ...