Fabric OS Administrator’s Guide
469
53-1001763-02
Inter-fabric link configuration
21
This port can now connect to another switch.
For related FC-FC Routing commands, see fcrEdgeShow, fcrXlateConfig, fcrConfigure, and
fcrProxyConfig in the
Fabric OS Command Reference
.
A Fibre Channel router can interconnect multiple fabrics. EX_Ports or VEX_Ports attached to
more than one edge fabric must configure a different fabric ID for each edge fabric.
3. (
Optional
) Configure FC router port cost, if you want to change the default values. For
information about using FC router port cost operations, see
“FC Router port cost configuration”
on page 471.
4. (
Optional
) Set up ISL or EX_Port trunking. For information on trunking setup, see
“Configuring
EX_Port frame trunking”
on page 476.
5. Enter the portEnable command to enable the ports that you disabled in
step 1
.
switch:admin>
portenable 7/10
6. Physically attach ISLs from the Fibre Channel router to the edge fabric.
7. Enter the portCfgShow command to view ports that are persistently disabled.
FC ports on the Brocade 7500 and 7800 switches and FR4-18i and FX8-24 blades are
configured as persistently disabled by default, to avoid inadvertent fabric merges when
installing a new FC router.
switch:admin>
portcfgshow 7/10
Area Number: 74
Speed Level: AUTO
Trunk Port OFF
Long Distance OFF
VC Link Init OFF
Locked L_Port OFF
Locked G_Port OFF
Disabled E_Port OFF
ISL R_RDY Mode OFF
RSCN Suppressed OFF
Persistent Disable OFF
NPIV capability ON
EX Port ON
Mirror Port ON
FC Fastwrite
ON
8. After identifying such ports, enter the portCfgPersistentEnable command to enable the port,
and then the portCfgShow command to verify the port is enabled.
switch:admin>
portcfgpersistentenable 7/10
switch:admin>
portcfgshow 7/10
Area Number: 74
Speed Level: AUTO
Trunk Port OFF
Long Distance OFF
VC Link Init OFF
Locked L_Port OFF
Locked G_Port OFF
Disabled E_Port OFF
ISL R_RDY Mode OFF
RSCN Suppressed OFF
Persistent Disable OFF
NPIV capability ON
Содержание 53-1001763-02
Страница 1: ...53 1001763 02 13 September 2010 Fabric OS Administrator s Guide Supporting Fabric OS v6 4 0 ...
Страница 4: ...iv Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 24: ...xxiv Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 28: ...xxviii Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 32: ...xxxii Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 40: ...xl Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 42: ...2 Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 54: ...14 Fabric OS Administrator s Guide 53 1001763 02 High availability of daemon processes 1 ...
Страница 74: ...34 Fabric OS Administrator s Guide 53 1001763 02 Basic connections 2 ...
Страница 102: ...62 Fabric OS Administrator s Guide 53 1001763 02 Audit log configuration 3 ...
Страница 156: ...116 Fabric OS Administrator s Guide 53 1001763 02 The authentication model using RADIUS and LDAP 5 ...
Страница 214: ...174 Fabric OS Administrator s Guide 53 1001763 02 Management interface security 7 ...
Страница 228: ...188 Fabric OS Administrator s Guide 53 1001763 02 Brocade configuration form 8 ...
Страница 276: ...236 Fabric OS Administrator s Guide 53 1001763 02 Creating a logical fabric using XISLs 10 ...
Страница 404: ...364 Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 440: ...400 Fabric OS Administrator s Guide 53 1001763 02 Performance data collection 17 ...
Страница 464: ...424 Fabric OS Administrator s Guide 53 1001763 02 Disabling bottleneck detection on a switch 18 ...
Страница 480: ...440 Fabric OS Administrator s Guide 53 1001763 02 F_Port masterless trunking 19 ...
Страница 494: ...454 Fabric OS Administrator s Guide 53 1001763 02 Buffer credit recovery 20 ...
Страница 560: ...520 Fabric OS Administrator s Guide 53 1001763 02 Port indexing on the Brocade DCX 4S backbone C ...
Страница 574: ...534 Fabric OS Administrator s Guide 53 1001763 02 Hexadecimal overview E ...