384
Fabric OS Administrator’s Guide
53-1001763-02
Advanced Performance Monitoring overview
17
•
ISL monitors measure the traffic transmitted through an InterSwitch Link (ISL) to different
destination domains.
•
Top Talkers monitors measure the flows that are major consumers of bandwidth on a switch or
port.
The type of monitors supported depends on the switch model, as shown in
Table 81
.
NOTE
Advanced Performance Monitoring is not supported on VE_Ports and EX_Ports. If you issue
commands for any Advanced Performance Monitors on VE_Ports or EX_Ports you will receive error
messages.
Virtual Fabrics considerations for Advanced Performance Monitoring
In a fabric with Virtual Fabrics enabled, the number of logical switches that can be configured with
monitors is restricted.
Table 82
lists the platforms that support logical switches and, for each
platform, the maximum number of logical switches that can support performance monitors.
Each logical switch can have its own set of performance monitors. The installation of monitors is
restricted to the ports that are present in the respective logical switch.
•
Top Talker and end-to-end monitors are supported on the default logical switch, the base
switch, and user-defined logical switches.
•
Frame monitors are not supported on logical ISLs (LISLs) in user-defined logical switches.
•
ISL monitors are not supported on any of the platforms listed in
Table 82
.
If you move a port from one logical switch to another, the behavior of monitors installed on that port
is as follows:
•
Frame monitor: Any frame monitors on the port are deleted. To keep the frame monitor, you
must manually install it on the port after the move.
TABLE 81
Types of monitors supported on Brocade switch models
Platform
Monitors:
EE
Frame ISL
Top Talker
Brocade 300, 5300, 7800
Yes Yes
No
Yes
Brocade 5410, 5424, 5450, and 5480
Yes Yes
No
No
Brocade 4100, 4900, 5000, 7500, 7500E, 7600, and 48000
Yes Yes
Yes Yes
Brocade 5100, 8000
1
, VA-40FC, Brocade Encryption Switch,
Brocade DCX, Brocade DCX-4S
1.
For the Brocade 8000, performance monitoring is supported only on the FC ports and not on the CEE ports.
Yes Yes
No
Yes
TABLE 82
Number of logical switches that support performance monitors
Platform
Maximum number of logical switches supported
Maximum number of logical switches on which
monitors are supported
Brocade DCX
8
4
Brocade DCX-4S
8
4
Brocade 5100
Brocade VA-40FC
3
3
Brocade 5300
4
3
Содержание 53-1001763-02
Страница 1: ...53 1001763 02 13 September 2010 Fabric OS Administrator s Guide Supporting Fabric OS v6 4 0 ...
Страница 4: ...iv Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 24: ...xxiv Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 28: ...xxviii Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 32: ...xxxii Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 40: ...xl Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 42: ...2 Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 54: ...14 Fabric OS Administrator s Guide 53 1001763 02 High availability of daemon processes 1 ...
Страница 74: ...34 Fabric OS Administrator s Guide 53 1001763 02 Basic connections 2 ...
Страница 102: ...62 Fabric OS Administrator s Guide 53 1001763 02 Audit log configuration 3 ...
Страница 156: ...116 Fabric OS Administrator s Guide 53 1001763 02 The authentication model using RADIUS and LDAP 5 ...
Страница 214: ...174 Fabric OS Administrator s Guide 53 1001763 02 Management interface security 7 ...
Страница 228: ...188 Fabric OS Administrator s Guide 53 1001763 02 Brocade configuration form 8 ...
Страница 276: ...236 Fabric OS Administrator s Guide 53 1001763 02 Creating a logical fabric using XISLs 10 ...
Страница 404: ...364 Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 440: ...400 Fabric OS Administrator s Guide 53 1001763 02 Performance data collection 17 ...
Страница 464: ...424 Fabric OS Administrator s Guide 53 1001763 02 Disabling bottleneck detection on a switch 18 ...
Страница 480: ...440 Fabric OS Administrator s Guide 53 1001763 02 F_Port masterless trunking 19 ...
Страница 494: ...454 Fabric OS Administrator s Guide 53 1001763 02 Buffer credit recovery 20 ...
Страница 560: ...520 Fabric OS Administrator s Guide 53 1001763 02 Port indexing on the Brocade DCX 4S backbone C ...
Страница 574: ...534 Fabric OS Administrator s Guide 53 1001763 02 Hexadecimal overview E ...