Test and restore firmware on enterprise-class platforms
9
c. Confirm the evaluation version of firmware is now running on the active CP by entering the
firmwareShow command.
9. Update firmware on the standby CP.
a. Connect to the enterprise-class platform on the standby CP, which is the old active CP.
b. Enter the firmwareDownload command with the -s -b -n operands. This ensures that the
following steps are successful.
At this point the firmware should download to the standby CP only and reboot it. The
current enterprise-class platform session will be disconnected.
c. Wait one minute for the standby CP to reboot, and then connect to the enterprise-class
platform and log in as admin.
d. Enter the firmwareShow command to confirm that
both
primary partitions now have the
test drive firmware in place.
You are now ready to evaluate the new version of firmware.
ATTENTION
Stop! If you want to
restore
the firmware, stop here
and skip ahead to
step 12
; otherwise,
continue to
step 10
to commit the firmware on both CPs, which completes the firmware
download.
10. Perform a commit on the standby CP.
From the current enterprise-class platform session on the standby CP, enter the
firmwareCommit command to update the secondary partition with new firmware. It takes
several minutes to complete the commit operation. Do not do anything on the enterprise-class
platform while this operation is in process.
11. Perform a commit on the active CP.
a. From the current enterprise-class platform session on the active CP, enter the
firmwareShow command and confirm that only the active CP secondary partition contains
the old firmware.
b. Enter the firmwareCommit command to update the secondary partition with the new
firmware. It takes several minutes to complete the commit operation. Do not do anything
on the enterprise-class platform while this operation is in process.
c. Upon completion of the firmwareCommit command, type the firmwareShow command to
confirm both partitions on both CPs contain the new firmware.
d. Enter the haShow command to confirm that the HA state is in sync.
ATTENTION
Stop! If you have completed
step 11
, then you have committed the firmware on both CPs and
you have completed the firmware download procedure.
12. Restore the firmware on the standby CP.
In the current enterprise-class platform session for the standby CP, enter the firmwareRestore
command. The standby CP will reboot and the current enterprise-class platform session will
end. Both partitions will have the same Fabric OS after several minutes.
13. Perform haFailover on the active CP.
Содержание 53-1001763-02
Страница 1: ...53 1001763 02 13 September 2010 Fabric OS Administrator s Guide Supporting Fabric OS v6 4 0 ...
Страница 4: ...iv Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 24: ...xxiv Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 28: ...xxviii Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 32: ...xxxii Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 40: ...xl Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 42: ...2 Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 54: ...14 Fabric OS Administrator s Guide 53 1001763 02 High availability of daemon processes 1 ...
Страница 74: ...34 Fabric OS Administrator s Guide 53 1001763 02 Basic connections 2 ...
Страница 102: ...62 Fabric OS Administrator s Guide 53 1001763 02 Audit log configuration 3 ...
Страница 156: ...116 Fabric OS Administrator s Guide 53 1001763 02 The authentication model using RADIUS and LDAP 5 ...
Страница 214: ...174 Fabric OS Administrator s Guide 53 1001763 02 Management interface security 7 ...
Страница 228: ...188 Fabric OS Administrator s Guide 53 1001763 02 Brocade configuration form 8 ...
Страница 276: ...236 Fabric OS Administrator s Guide 53 1001763 02 Creating a logical fabric using XISLs 10 ...
Страница 404: ...364 Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 440: ...400 Fabric OS Administrator s Guide 53 1001763 02 Performance data collection 17 ...
Страница 464: ...424 Fabric OS Administrator s Guide 53 1001763 02 Disabling bottleneck detection on a switch 18 ...
Страница 480: ...440 Fabric OS Administrator s Guide 53 1001763 02 F_Port masterless trunking 19 ...
Страница 494: ...454 Fabric OS Administrator s Guide 53 1001763 02 Buffer credit recovery 20 ...
Страница 560: ...520 Fabric OS Administrator s Guide 53 1001763 02 Port indexing on the Brocade DCX 4S backbone C ...
Страница 574: ...534 Fabric OS Administrator s Guide 53 1001763 02 Hexadecimal overview E ...