Fabric OS Administrator’s Guide
389
53-1001763-02
Frame monitoring
17
Frame monitoring
Frame monitoring counts the number of times a frame with a particular pattern is transmitted by a
port and generates alerts when thresholds are crossed. Frame monitoring is achieved by defining a
filter, or frame type, for a particular purpose. The frame type can be a standard type (for example, a
SCSI read command filter that counts the number of SCSI read commands that have been
transmitted by the port) or a user-defined frame type customized for your particular use. For a
complete list of the standard, pre-defined frame types, see the fmConfig command description in
the
Fabric OS Command Reference
.
NOTE
The Advanced Performance Monitoring license is required to use the fmConfig command. The
monitoring functionality, however, also requires the Fabric Watch license. When you configure
actions and alerts through the fmConfig command, Fabric Watch uses these values and generates
alerts based on the configuration. If you do not have a Fabric Watch license, these values are
ignored. See the
Fabric Watch Administrator’s Guide
for more information about using Fabric Watch.
The maximum number of frame monitors and offsets per port depends on the platform.
Table 83
shows the maximum number of frame monitors, in any combination of standard and user-defined
frame types, and the maximum number of offsets per port.
The actual number of frame monitors that can be configured on a port depends on the complexity
of the frame types. For trunked ports, the frame monitor is configured on the trunk master.
Virtual Fabrics considerations: Frame monitors are not supported on logical ISLs (LISLs), but are
supported on ISLs and extended ISLs (XISLs).
This section describes frame monitoring using the fmConfig command. This command enhances
and replaces the following legacy commands:
•
perfAddIPMonitor
•
perfAddRWMonitor
•
perfAddReadMonitor
•
perfAddSCSIMonitor
•
perfAddUserMonitor
•
perfAddWriteMonitor
•
perfDelFilterMonitor
TABLE 83
Maximum number of frame monitors and offsets per port
Platform
Max number of frame monitors per port Max number of offsets per port
Brocade 300, 5300, 5410, 5424, 5450,
5480, and 7800
8
8
Brocade 4100, 4900, 7500, 7500E, and
7600
12
16
Brocade 5000, 5100, 8000, VA-40FC, DCX,
DCX-4S, and Brocade Encryption Switch
12
20
Brocade 4800 (all blades except FC4-48)
12
16
Brocade 48000 (FC4-48 blade):
•
Lower 16 ports (0 through 15)
•
Middle 16 ports (16 through 31)
•
Upper 16 ports (32 through 47)
12
6
0
16
12
0
Содержание 53-1001763-02
Страница 1: ...53 1001763 02 13 September 2010 Fabric OS Administrator s Guide Supporting Fabric OS v6 4 0 ...
Страница 4: ...iv Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 24: ...xxiv Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 28: ...xxviii Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 32: ...xxxii Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 40: ...xl Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 42: ...2 Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 54: ...14 Fabric OS Administrator s Guide 53 1001763 02 High availability of daemon processes 1 ...
Страница 74: ...34 Fabric OS Administrator s Guide 53 1001763 02 Basic connections 2 ...
Страница 102: ...62 Fabric OS Administrator s Guide 53 1001763 02 Audit log configuration 3 ...
Страница 156: ...116 Fabric OS Administrator s Guide 53 1001763 02 The authentication model using RADIUS and LDAP 5 ...
Страница 214: ...174 Fabric OS Administrator s Guide 53 1001763 02 Management interface security 7 ...
Страница 228: ...188 Fabric OS Administrator s Guide 53 1001763 02 Brocade configuration form 8 ...
Страница 276: ...236 Fabric OS Administrator s Guide 53 1001763 02 Creating a logical fabric using XISLs 10 ...
Страница 404: ...364 Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 440: ...400 Fabric OS Administrator s Guide 53 1001763 02 Performance data collection 17 ...
Страница 464: ...424 Fabric OS Administrator s Guide 53 1001763 02 Disabling bottleneck detection on a switch 18 ...
Страница 480: ...440 Fabric OS Administrator s Guide 53 1001763 02 F_Port masterless trunking 19 ...
Страница 494: ...454 Fabric OS Administrator s Guide 53 1001763 02 Buffer credit recovery 20 ...
Страница 560: ...520 Fabric OS Administrator s Guide 53 1001763 02 Port indexing on the Brocade DCX 4S backbone C ...
Страница 574: ...534 Fabric OS Administrator s Guide 53 1001763 02 Hexadecimal overview E ...