134
Fabric OS Administrator’s Guide
53-1001763-02
ACL policy management
7
Policies with the same state are grouped together in a
Policy Set
. Each switch has the following two
sets:
•
Active policy set, which contains ACL policies being enforced by the switch.
•
Defined policy set, which contains a copy of all ACL policies on the switch.
When a policy is activated, the defined policy either replaces the policy with the same name in the
active set or becomes a new active policy. If a policy appears in the defined set but not in the active
set, the policy was saved but has not been activated. If a policy with the same name appears in
both the defined and active sets but they have different values, then the policy has been modified
but the changes have not been activated.
Admin Domain considerations: ACL management can be done on AD255 and in AD0 only if there
are no user-defined Admin Domains. Both AD0 (when no other user-defined Admin Domains exist)
and AD255 provide an unfiltered view of the fabric.
Virtual Fabric considerations: ACL policies such as DCC, SCC, and FCS can be configured on each
logical switch. The limit for security policy database size is set to 1Mb per logical switch.
Policy members
The FCS, DCC and SCC policy members are specified by device port WWN, switch WWN, domain
IDs, or switch names, depending on the policy. The valid methods for specifying policy members
are listed in
Table 25
.
ACL policy management
All policy modifications are temporarily stored in volatile memory until those changes are saved or
activated. You can create multiple sessions to the switch from one or more hosts. It is
recommended you make changes from one switch only to prevent multiple transactions from
occurring. Each logical switch will have its own access control list.
The FCS, SCC and DCC policies in Secure Fabric OS are not interchangeable with Fabric OS FCS,
SCC and DCC policies. Uploading and saving a copy of the Fabric OS configuration after creating
policies is strongly recommended. For more information on configuration uploads, see the
Chapter
8, “Maintaining the Switch Configuration File”
.
NOTE
All changes, including the creation of new policies, are saved and activated on the local switch only—
unless the switch is in a fabric that has a strict or tolerant fabric-wide consistency policy for the ACL
policy type for SCC or DCC. See
“Policy database distribution”
on page 158 for more information on
the database settings and fabric-wide consistency policy.
TABLE 25
Valid methods for specifying policy members
Policy name
Device port WWN
Switch WWN
Domain ID
Switch name
FCS_POLICY
No
Yes
Yes
Yes
DCC_POLICY_
nnn
Yes
Yes
Yes
Yes
SCC_POLICY
No
Yes
Yes
Yes
Содержание 53-1001763-02
Страница 1: ...53 1001763 02 13 September 2010 Fabric OS Administrator s Guide Supporting Fabric OS v6 4 0 ...
Страница 4: ...iv Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 24: ...xxiv Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 28: ...xxviii Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 32: ...xxxii Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 40: ...xl Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 42: ...2 Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 54: ...14 Fabric OS Administrator s Guide 53 1001763 02 High availability of daemon processes 1 ...
Страница 74: ...34 Fabric OS Administrator s Guide 53 1001763 02 Basic connections 2 ...
Страница 102: ...62 Fabric OS Administrator s Guide 53 1001763 02 Audit log configuration 3 ...
Страница 156: ...116 Fabric OS Administrator s Guide 53 1001763 02 The authentication model using RADIUS and LDAP 5 ...
Страница 214: ...174 Fabric OS Administrator s Guide 53 1001763 02 Management interface security 7 ...
Страница 228: ...188 Fabric OS Administrator s Guide 53 1001763 02 Brocade configuration form 8 ...
Страница 276: ...236 Fabric OS Administrator s Guide 53 1001763 02 Creating a logical fabric using XISLs 10 ...
Страница 404: ...364 Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 440: ...400 Fabric OS Administrator s Guide 53 1001763 02 Performance data collection 17 ...
Страница 464: ...424 Fabric OS Administrator s Guide 53 1001763 02 Disabling bottleneck detection on a switch 18 ...
Страница 480: ...440 Fabric OS Administrator s Guide 53 1001763 02 F_Port masterless trunking 19 ...
Страница 494: ...454 Fabric OS Administrator s Guide 53 1001763 02 Buffer credit recovery 20 ...
Страница 560: ...520 Fabric OS Administrator s Guide 53 1001763 02 Port indexing on the Brocade DCX 4S backbone C ...
Страница 574: ...534 Fabric OS Administrator s Guide 53 1001763 02 Hexadecimal overview E ...