Fabric OS Administrator’s Guide
487
53-1001763-02
LSAN zone configuration
21
How LSAN zone binding works
LSAN zone binding uses an
FC router matrix
, which specifies pairs of FC routers in the backbone
fabric that can access each other, and an
LSAN fabric matrix
, which specifies pairs of edge fabrics
that can access each other.
You set up LSAN zone binding using the fcrLsanMatrix command. This command has two options:
-fcr and -lsan. The -fcr option is for creating and updating the FC router matrix, and the -lsan option
is used for creating and updating the LSAN fabric matrix.
NOTE
Best practice: Use this feature in a backbone fabric in which all FC routers are running Fabric OS
v6.1.0 or later.
When you set up LSAN zone binding on the local FC router (running Fabric OS v6.1.0 or later), the
resultant matrix database is automatically distributed to all of the v6.1.0 or later FC routers in the
backbone fabric. You do not need to set up LSAN zone binding on the other FC routers unless those
FC routers are running Fabric OS versions earlier than v6.1.0.
If a new FC router joins the backbone fabric, the matrix database is automatically distributed to
that FC router.
Note the following for FC routers running a Fabric OS version earlier than 6.1.0:
•
The matrix database is not automatically distributed from this FC router to other FC routers.
•
You must manually configure the LSAN fabric matrix on these FC routers to match the other FC
routers in the backbone fabric.
If you have a dual backbone configuration, where two backbone fabrics share edge fabrics, the
LSAN fabric matrix and FC router matrix settings for the shared edge fabrics must be the same on
both backbone fabrics. The matrix databases are
not
automatically propagated from one backbone
fabric to another, so you must ensure that both backbone fabrics have the same matrix settings.
NOTE
You can use LSAN zone binding along with the LSAN tagging to achieve better scalability and
performance. See
“LSAN zone policies using LSAN tagging”
on page 481 for information about using
the Enforce LSAN tag.
FC router matrix definition
Depending on the structure of the backbone fabric, you can specify pairs of FC routers that can
access each other. For the metaSAN shown in
Figure 75
, the following FC routers can access each
other:
•
FC router 1 and FC router 2
•
FC router 3 and FC router 4
Because there is no device sharing between the two groups of FC routers, you can use the
fcrLsanMatrix command with the -fcr option to create the corresponding FC router matrix:
fcrlsanmatrix --add -fcr
wwn1
wwn2
fcrlsanmatrix --add -fcr
wwn3
wwn4
where
wwn1
,
wwn2
,
wwn3
, and
wwn4
are the WWNs of the four FC routers.
Now edge fabrics 1, 2, 3, 7, and 8 can access each other, and edge fabrics 4, 5, 6, and 9 can
access each other; however, edge fabrics in one group cannot access edge fabrics in the other
group.
Содержание 53-1001763-02
Страница 1: ...53 1001763 02 13 September 2010 Fabric OS Administrator s Guide Supporting Fabric OS v6 4 0 ...
Страница 4: ...iv Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 24: ...xxiv Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 28: ...xxviii Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 32: ...xxxii Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 40: ...xl Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 42: ...2 Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 54: ...14 Fabric OS Administrator s Guide 53 1001763 02 High availability of daemon processes 1 ...
Страница 74: ...34 Fabric OS Administrator s Guide 53 1001763 02 Basic connections 2 ...
Страница 102: ...62 Fabric OS Administrator s Guide 53 1001763 02 Audit log configuration 3 ...
Страница 156: ...116 Fabric OS Administrator s Guide 53 1001763 02 The authentication model using RADIUS and LDAP 5 ...
Страница 214: ...174 Fabric OS Administrator s Guide 53 1001763 02 Management interface security 7 ...
Страница 228: ...188 Fabric OS Administrator s Guide 53 1001763 02 Brocade configuration form 8 ...
Страница 276: ...236 Fabric OS Administrator s Guide 53 1001763 02 Creating a logical fabric using XISLs 10 ...
Страница 404: ...364 Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 440: ...400 Fabric OS Administrator s Guide 53 1001763 02 Performance data collection 17 ...
Страница 464: ...424 Fabric OS Administrator s Guide 53 1001763 02 Disabling bottleneck detection on a switch 18 ...
Страница 480: ...440 Fabric OS Administrator s Guide 53 1001763 02 F_Port masterless trunking 19 ...
Страница 494: ...454 Fabric OS Administrator s Guide 53 1001763 02 Buffer credit recovery 20 ...
Страница 560: ...520 Fabric OS Administrator s Guide 53 1001763 02 Port indexing on the Brocade DCX 4S backbone C ...
Страница 574: ...534 Fabric OS Administrator s Guide 53 1001763 02 Hexadecimal overview E ...