82
Fabric OS Administrator’s Guide
53-1001763-02
Frame Redirection
4
FIGURE 12
Single Host and Target
Figure 12
demonstrates the flow of frame redirection traffic. A frame starts at the host with a
destination to the target. The port where the appliance is attached to the host switch acts as the
virtual initiator and the port where the appliance is attached to the target switch is the virtual
target.
Creating a frame redirect zone
The first time this command is run the following zone objects are created by default:
•
The base zone object, "red_______base".
•
The RD zone configuration, "r_e_d_i_r_c__fg".
1. Connect to the switch and log in using an account assigned to the admin role.
2. Enter the zone
–-
rdcreate command.
3. Enter the cfgSave command to save the frame redirect zones to the defined configuration.
Example of creating a frame redirect zone.
The following example creates an RD Zone, given a host (10:10:10:10:10:10:10:10), target
(20:20:20:20:20:20:20:20), VI (30:30:30:30:30:30:30:30), and VT (40:40:40:40:40:40:40:40):
switch:admin>
zone --rdcreate 10:10:10:10:10:10:10:10 20:20:20:20:20:20:20:20 \
30:30:30:30:30:30:30:30 40:40:40:40:40:40:40:40 restartable noFCR
Deleting a frame redirect zone
1. Connect to the switch and log in using an account assigned to the admin role.
2. Enter the zone
--
rdDelete command to remove the base RD zone, "red_______base".
When the base zone is removed, the RD zone configuration "r_e_d_i_r_c__fg” is removed as
well.
3. Enter the zone
--
cfgSave command to save changes to the defined configuration.
Example of deleting a frame redirect zone.
switch:admin>
zone --rddelete \
red_0917_10_10_10_10_10_10_10_10_20_20_20_20_20_20_20_20
Viewing redirect zones
1. Connect to the switch and log in using an account assigned to the admin role.
2. Enter the cfgShow command.
Содержание 53-1001763-02
Страница 1: ...53 1001763 02 13 September 2010 Fabric OS Administrator s Guide Supporting Fabric OS v6 4 0 ...
Страница 4: ...iv Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 24: ...xxiv Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 28: ...xxviii Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 32: ...xxxii Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 40: ...xl Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 42: ...2 Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 54: ...14 Fabric OS Administrator s Guide 53 1001763 02 High availability of daemon processes 1 ...
Страница 74: ...34 Fabric OS Administrator s Guide 53 1001763 02 Basic connections 2 ...
Страница 102: ...62 Fabric OS Administrator s Guide 53 1001763 02 Audit log configuration 3 ...
Страница 156: ...116 Fabric OS Administrator s Guide 53 1001763 02 The authentication model using RADIUS and LDAP 5 ...
Страница 214: ...174 Fabric OS Administrator s Guide 53 1001763 02 Management interface security 7 ...
Страница 228: ...188 Fabric OS Administrator s Guide 53 1001763 02 Brocade configuration form 8 ...
Страница 276: ...236 Fabric OS Administrator s Guide 53 1001763 02 Creating a logical fabric using XISLs 10 ...
Страница 404: ...364 Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 440: ...400 Fabric OS Administrator s Guide 53 1001763 02 Performance data collection 17 ...
Страница 464: ...424 Fabric OS Administrator s Guide 53 1001763 02 Disabling bottleneck detection on a switch 18 ...
Страница 480: ...440 Fabric OS Administrator s Guide 53 1001763 02 F_Port masterless trunking 19 ...
Страница 494: ...454 Fabric OS Administrator s Guide 53 1001763 02 Buffer credit recovery 20 ...
Страница 560: ...520 Fabric OS Administrator s Guide 53 1001763 02 Port indexing on the Brocade DCX 4S backbone C ...
Страница 574: ...534 Fabric OS Administrator s Guide 53 1001763 02 Hexadecimal overview E ...