Fabric OS Administrator’s Guide
31
53-1001763-02
Chassis names
2
Chassis names
Brocade recommends that you customize the chassis name for each platform. Some system logs
identify devices by platform names; if you assign meaningful platform names, logs are more useful.
All chassis names have a limit of 15 characters, except for the Brocade 300, 5100, 5300, and
VA-40FC switches, and the 5410, 5424, 5450, and 5480 embedded switches, which allow 31
characters. Chassis names must begin with a letter, and can contain letters, numbers, or the
underscore character.
Customizing chassis names
1. Connect to the switch and log in as admin.
2. Enter the chassisName command.
ecp:admin>
chassisname
newname
3. Record the new chassis name for future reference.
Switch activation and deactivation
By default, the switch is enabled after power is applied and diagnostics and switch initialization
routines have finished. You can disable and re-enable it as necessary.
Disabling a switch
1. Connect to the switch and log in using an account assigned to the admin role.
2. Enter the switchDisable command.
All Fibre Channel ports on the switch are taken offline. If the switch was part of a fabric, the
fabric is reconfigured.
Enabling a switch
1. Connect to the switch and log in using an account assigned to the admin role.
2. Enter the switchEnable command.
All Fibre Channel ports that passed POST are enabled. If the switch has interswitch links (ISLs)
to a fabric, it joins the fabric.
Switch and enterprise-class platform shutdown
To avoid corrupting your file system, Brocade recommends that you perform graceful shutdowns of
Brocade switches and enterprise-class platforms.
Warm reboot
refers to shutting down the appliance per the instructions below, also known as a
graceful shutdown
.
Cold boot
refers to shutting down the appliance by suddenly shutting down
power and then turning it back on, also known as a
hard boot
.
Содержание 53-1001763-02
Страница 1: ...53 1001763 02 13 September 2010 Fabric OS Administrator s Guide Supporting Fabric OS v6 4 0 ...
Страница 4: ...iv Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 24: ...xxiv Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 28: ...xxviii Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 32: ...xxxii Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 40: ...xl Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 42: ...2 Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 54: ...14 Fabric OS Administrator s Guide 53 1001763 02 High availability of daemon processes 1 ...
Страница 74: ...34 Fabric OS Administrator s Guide 53 1001763 02 Basic connections 2 ...
Страница 102: ...62 Fabric OS Administrator s Guide 53 1001763 02 Audit log configuration 3 ...
Страница 156: ...116 Fabric OS Administrator s Guide 53 1001763 02 The authentication model using RADIUS and LDAP 5 ...
Страница 214: ...174 Fabric OS Administrator s Guide 53 1001763 02 Management interface security 7 ...
Страница 228: ...188 Fabric OS Administrator s Guide 53 1001763 02 Brocade configuration form 8 ...
Страница 276: ...236 Fabric OS Administrator s Guide 53 1001763 02 Creating a logical fabric using XISLs 10 ...
Страница 404: ...364 Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 440: ...400 Fabric OS Administrator s Guide 53 1001763 02 Performance data collection 17 ...
Страница 464: ...424 Fabric OS Administrator s Guide 53 1001763 02 Disabling bottleneck detection on a switch 18 ...
Страница 480: ...440 Fabric OS Administrator s Guide 53 1001763 02 F_Port masterless trunking 19 ...
Страница 494: ...454 Fabric OS Administrator s Guide 53 1001763 02 Buffer credit recovery 20 ...
Страница 560: ...520 Fabric OS Administrator s Guide 53 1001763 02 Port indexing on the Brocade DCX 4S backbone C ...
Страница 574: ...534 Fabric OS Administrator s Guide 53 1001763 02 Hexadecimal overview E ...