Fabric OS Administrator’s Guide
353
53-1001763-02
Admin Domain management for physical fabric administrators
15
where:
4. Copy the newly added zones in AD0 to the zone configuration.
cfgadd "
cfgName
", "
member
[;
member
]"
5. Enable the configuration to complete the transaction.
cfgenable
cfgName
6. Switch to the AD255 context.
ad --select 255
7. Explicitly add devices that are present in the user-defined ADs to AD0.
ad --add AD0 -d "
dev_list
"
8. Enter the ad
--
apply command to save the Admin Domain definition and directly apply the
definitions to the fabric.
ad --apply
At this point, all of the devices in the user-defined ADs are also defined and zoned in AD0.
9. Clear the user-defined ADs.
ad --clear -f
10. Enter the ad
--
apply command to save the Admin Domain definition and directly apply the
definitions to the fabric.
ad --apply
All user-defined Admin Domains have now been removed, but all device communication that
was allowed with the original Admin Domain configuration is still permitted in the context of
AD0.
Example
The following example assumes the configuration shown in
Figure 56
on page 354:
•
Three Admin Domains: AD0, plus two user-defined Admin Domains (AD1 and AD2)
•
AD0 has two devices, WWN1 and WWN2, in the AD0_RedZone
•
AD1 has two devices, WWN2 and WWN3, in the AD1_BlueZone
•
AD2 has two devices, WWN3 and WWN4, in the AD2_GreenZone
•
The device WWN2 is in both AD0 and AD1.
At the conclusion of the procedure, all devices and zones are moved to AD0, and the user-defined
Admin Domains are deleted, as shown in
Figure 57
.
source_AD
Name of the user-defined AD from which you are copying the zone.
source_name
Name of the zone to be copied.
dest_name
Name to give the zone after it is copied to AD0.
Содержание 53-1001763-02
Страница 1: ...53 1001763 02 13 September 2010 Fabric OS Administrator s Guide Supporting Fabric OS v6 4 0 ...
Страница 4: ...iv Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 24: ...xxiv Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 28: ...xxviii Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 32: ...xxxii Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 40: ...xl Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 42: ...2 Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 54: ...14 Fabric OS Administrator s Guide 53 1001763 02 High availability of daemon processes 1 ...
Страница 74: ...34 Fabric OS Administrator s Guide 53 1001763 02 Basic connections 2 ...
Страница 102: ...62 Fabric OS Administrator s Guide 53 1001763 02 Audit log configuration 3 ...
Страница 156: ...116 Fabric OS Administrator s Guide 53 1001763 02 The authentication model using RADIUS and LDAP 5 ...
Страница 214: ...174 Fabric OS Administrator s Guide 53 1001763 02 Management interface security 7 ...
Страница 228: ...188 Fabric OS Administrator s Guide 53 1001763 02 Brocade configuration form 8 ...
Страница 276: ...236 Fabric OS Administrator s Guide 53 1001763 02 Creating a logical fabric using XISLs 10 ...
Страница 404: ...364 Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 440: ...400 Fabric OS Administrator s Guide 53 1001763 02 Performance data collection 17 ...
Страница 464: ...424 Fabric OS Administrator s Guide 53 1001763 02 Disabling bottleneck detection on a switch 18 ...
Страница 480: ...440 Fabric OS Administrator s Guide 53 1001763 02 F_Port masterless trunking 19 ...
Страница 494: ...454 Fabric OS Administrator s Guide 53 1001763 02 Buffer credit recovery 20 ...
Страница 560: ...520 Fabric OS Administrator s Guide 53 1001763 02 Port indexing on the Brocade DCX 4S backbone C ...
Страница 574: ...534 Fabric OS Administrator s Guide 53 1001763 02 Hexadecimal overview E ...