358
Fabric OS Administrator’s Guide
53-1001763-02
SAN management with Admin Domains
15
Displaying an Admin Domain configuration
You can display the membership information and zone database information of a specified Admin
Domain. Note the following differences in the information displayed based on the Admin Domain:
•
AD255: if you do not specify the AD_name or number, all information about all existing Admin
Domains is displayed.
•
AD0-AD254 contexts: the membership of the current Admin Domain is displayed.
•
AD0: the device and switch list members are categorized into implicit and explicit member
lists.
1. Connect to the switch and log in as any user type.
2. Enter the ad
--
show command.
ad --show
If you are in the AD0 context, you can use the -i option to display the implicit membership list of
AD0; otherwise, only the explicit membership list is displayed.
ad --show -i
If you are in the AD255 context, all Admin Domain configuration from the transaction buffer,
defined configuration, and effective configuration is displayed, unless you use the -m option:
ad --show
ad_id
-m
mode
where
ad_id
is the Admin Domain for which you want to display information and
mode
is one of
the following:
•
0 to display the Admin Domain configuration in the current transaction buffer.
•
1 to display the Admin Domain configuration stored in the persistent memory (defined
configuration).
•
2 to display the currently enforced Admin Domain configuration (effective configuration).
Example
The following example displays membership information about AD1.
switch:AD1:admin>
ad --show
Current AD Number: 1 AD Name: TheSwitches
Effective configuration:
------------------------
AD Number: 1 AD Name: TheSwitches State: Active
Switch WWN members: 50:06:06:99:00:2a:e9:01;
50:00:51:e0:23:36:f9:01;
50:06:06:98:05:be:99:01;
Switching to a different Admin Domain context
You can switch between different Admin Domain contexts. This option creates a new shell with a
new Admin Domain context. If the corresponding Admin Domain is not activated, the operation
fails.
Содержание 53-1001763-02
Страница 1: ...53 1001763 02 13 September 2010 Fabric OS Administrator s Guide Supporting Fabric OS v6 4 0 ...
Страница 4: ...iv Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 24: ...xxiv Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 28: ...xxviii Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 32: ...xxxii Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 40: ...xl Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 42: ...2 Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 54: ...14 Fabric OS Administrator s Guide 53 1001763 02 High availability of daemon processes 1 ...
Страница 74: ...34 Fabric OS Administrator s Guide 53 1001763 02 Basic connections 2 ...
Страница 102: ...62 Fabric OS Administrator s Guide 53 1001763 02 Audit log configuration 3 ...
Страница 156: ...116 Fabric OS Administrator s Guide 53 1001763 02 The authentication model using RADIUS and LDAP 5 ...
Страница 214: ...174 Fabric OS Administrator s Guide 53 1001763 02 Management interface security 7 ...
Страница 228: ...188 Fabric OS Administrator s Guide 53 1001763 02 Brocade configuration form 8 ...
Страница 276: ...236 Fabric OS Administrator s Guide 53 1001763 02 Creating a logical fabric using XISLs 10 ...
Страница 404: ...364 Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 440: ...400 Fabric OS Administrator s Guide 53 1001763 02 Performance data collection 17 ...
Страница 464: ...424 Fabric OS Administrator s Guide 53 1001763 02 Disabling bottleneck detection on a switch 18 ...
Страница 480: ...440 Fabric OS Administrator s Guide 53 1001763 02 F_Port masterless trunking 19 ...
Страница 494: ...454 Fabric OS Administrator s Guide 53 1001763 02 Buffer credit recovery 20 ...
Страница 560: ...520 Fabric OS Administrator s Guide 53 1001763 02 Port indexing on the Brocade DCX 4S backbone C ...
Страница 574: ...534 Fabric OS Administrator s Guide 53 1001763 02 Hexadecimal overview E ...