224
Fabric OS Administrator’s Guide
53-1001763-02
Disabling Virtual Fabrics mode
10
1. Connect to the physical chassis and log in using an account assigned to the admin role with
the chassis-role permission.
2. Enter the following command to check whether VF mode is enabled:
fosconfig --show
3. Delete all Admin Domains, as described in
“Deleting all user-defined Admin Domains
non-disruptively”
on page 352.
4. Enter the following command to enable VF mode:
fosconfig --enable vf
5. Enter y at the prompt.
Example
The following example checks whether VF mode is enabled or disabled and then enables it.
switch:admin>
fosconfig --show
FC Routing service:
disabled
iSCSI service:
Service not supported on this Platform
iSNS client service:
Service not supported on this Platform
Virtual Fabric:
disabled
Ethernet Switch Service:
Service not supported on this Platform
switch:admin>
fosconfig --enable vf
WARNING:
This is a disruptive operation that requires a reboot to take
effect.
All EX ports will be disabled upon reboot.
Would you like to continue [Y/N]
y
VF has been enabled. Your system is being rebooted.
Disabling Virtual Fabrics mode
When you disable VF mode, the following occurs:
•
The CPs are rebooted.
•
If F_Port trunking is enabled on ports in the default switch, the F_Port trunking information is
deleted.
If you want to use Admin Domains in a fabric, you must first disable VF mode.
1. Connect to the physical chassis and log in using an account assigned to the admin role with
the chassis-role permission.
2. Enter the following command to check whether VF mode is disabled:
fosconfig --show
3. Delete all of the non-default logical switches, as described in
“Deleting a logical switch”
on
page 228.
4. Enter the following command to disable VF mode:
fosconfig --disable vf
5. Enter y at the prompt.
Содержание 53-1001763-02
Страница 1: ...53 1001763 02 13 September 2010 Fabric OS Administrator s Guide Supporting Fabric OS v6 4 0 ...
Страница 4: ...iv Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 24: ...xxiv Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 28: ...xxviii Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 32: ...xxxii Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 40: ...xl Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 42: ...2 Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 54: ...14 Fabric OS Administrator s Guide 53 1001763 02 High availability of daemon processes 1 ...
Страница 74: ...34 Fabric OS Administrator s Guide 53 1001763 02 Basic connections 2 ...
Страница 102: ...62 Fabric OS Administrator s Guide 53 1001763 02 Audit log configuration 3 ...
Страница 156: ...116 Fabric OS Administrator s Guide 53 1001763 02 The authentication model using RADIUS and LDAP 5 ...
Страница 214: ...174 Fabric OS Administrator s Guide 53 1001763 02 Management interface security 7 ...
Страница 228: ...188 Fabric OS Administrator s Guide 53 1001763 02 Brocade configuration form 8 ...
Страница 276: ...236 Fabric OS Administrator s Guide 53 1001763 02 Creating a logical fabric using XISLs 10 ...
Страница 404: ...364 Fabric OS Administrator s Guide 53 1001763 02 ...
Страница 440: ...400 Fabric OS Administrator s Guide 53 1001763 02 Performance data collection 17 ...
Страница 464: ...424 Fabric OS Administrator s Guide 53 1001763 02 Disabling bottleneck detection on a switch 18 ...
Страница 480: ...440 Fabric OS Administrator s Guide 53 1001763 02 F_Port masterless trunking 19 ...
Страница 494: ...454 Fabric OS Administrator s Guide 53 1001763 02 Buffer credit recovery 20 ...
Страница 560: ...520 Fabric OS Administrator s Guide 53 1001763 02 Port indexing on the Brocade DCX 4S backbone C ...
Страница 574: ...534 Fabric OS Administrator s Guide 53 1001763 02 Hexadecimal overview E ...