Additional information
X90 mobile system User's manual V 1.20 - Translation of the original manual
371
8.1.5 SystemTime
Name:
SystemTime
The starting time of a specific task class in µs can be read from this data point. The system time is latched at the
beginning of the cycle of the task class that contains this data point.
Information:
Because the DINT counter overflows and resets approximately every 70 minutes, it is only possible to
read out the relative system time.
Data type
Values
DINT
-2,147,483,648 to 2,147,483,647
8.1.6 TemperaturCPU
Name:
TemperaturCPU
The internal temperature of the CPU can be read from this data point.
Data type
Values
Information
INT
-32768 to 32767
Temperature in 1/10°C
8.1.7 TemperaturENV1
Name:
TemperaturENV1
The temperature of the memory module on the mainboard can be read from this data point.
Data type
Values
Information
INT
-32768 to 32767
Temperature in 1/10°C
8.1.8 TemperaturENV2
Name:
TemperaturENV2
The temperature of the circuit board can be read from this data point.
Data type
Values
Information
INT
-32768 to 32767
Temperature in 1/10°C
8.1.9 TemperaturENV3
Name:
TemperaturENV3
The temperature of the main relay can be read from this data point.
Data type
Values
Information
INT
-32768 to 32767
Temperature in 1/10°C
8.1.10 TemperaturENV4
Name:
TemperaturENV4
The temperature near the X1.C connector can be read from this data point.
Data type
Values
Information
INT
-32768 to 32767
Temperature in 1/10°C