X90 mobile modules
284
X90 mobile system User's manual V 1.20 - Translation of the original manual
Assembly B
Figure 112: System diagram - Structure of a fan with belt drive - Alternative bearing
Sensor usage:
Number of sensors
Usually 4 sensors. One sensor is sufficient for smaller drive units.
Sensor installation
Preferably vertical. Horizontal installation is also possible, if necessary.
Belt misalignment is particularly apparent in the axial direction.