X90 mobile modules
X90 mobile system User's manual V 1.20 - Translation of the original manual
195
5.4.1.5.10.9 FrequencyBandDmgFreq60rpm
Name:
FrequencyBand01DmgFreq60rpm to FrequencyBand32DmgFreq60rpm
Standardized damage frequency at 60 rpm if the frequency band is configured as speed-dependent.
This is multiplied with the configured velocity data point in the module to calculate the frequency band.
The standardized damage frequency must be specified in 1/100.
Data type
Values
Information
UINT
1 to 65,535
Bus controller default setting: 0
5.4.1.5.10.10 FrequencyBandDmgFreq60rpmRead
Name:
FrequencyBand01DmgFreq60rpmRead to FrequencyBand32DmgFreq60rpmRead
Register to read the standardized damage frequency at 60 rpm for the individual frequency bands.
The standardized damage frequency is specified in 1/100.
Data type
Values
UINT
1 to 65,535
5.4.1.5.10.11 FrequencyBandTolerance
Name:
FrequencyBand01Tolerance to FrequencyBand32Tolerance
If the frequency band is configured as speed-dependent, then this data point can be used to specify the frequency
band's width.
The
"FrequencyBandTolerance"
is subtracted once from the damage frequency calculated from
"ActSpeed"
and
"FrequencyBandDmgFreq60rpm"
to get the frequency band's lower frequency and added once to get its higher
frequency.
The tolerance must be specified in 1/100 Hz.
Data type
Values
UINT
0 to 65,535
5.4.1.5.10.12 FrequencyBandToleranceRead
Name:
FrequencyBand01ToleranceRead to FrequencyBand32ToleranceRead
Registers for reading the tolerance of individual frequency bands.
The tolerance is specified in 1/100 Hz.
Data type
Values
UINT
1 to 65,535
5.4.1.5.10.13 FrequencyBandLowerFrequency
Name:
FrequencyBand01LowerFrequency to FrequencyBand32LowerFrequency
Minimum frequency for calculating the frequency band if it is not speed-dependent.
The minimum frequency must be specified in 1/4 Hz.
Data type
Values
Information
UINT
1 to 40,000
Bus controller default setting: 0