X90 mobile modules
X90 mobile system User's manual V 1.20 - Translation of the original manual
319
5.7 Temperature modules
5.7.1 X90AT910.0x-00
Data sheet version: 1.20
5.7.1.1 General information
With the modular X90 mobile controller and I/O system, B&R is opening up new possibilities in mobile automation.
The comprehensive set of standardized components makes the X90 mobile system perfect for implementing flex-
ible automation concepts.
Option board X90AT910.0x-00 is integrated in the X90 mobile system and extends the functionality of the entire
system.
The AT option board offers 4 or 8 additional channels that can be used for current, voltage or temperature mea-
surement. It is also possible to use the analog inputs as PWM signal outputs or digital inputs (with toggling between
sink mode and source mode). Communication to the mainboard is implemented using X2X Link.
•
9 to 32 VDC
•
4 or 8 current, voltage, temperature or digital inputs or PWM outputs
•
Temperature measurement
•
X2X Link
5.7.1.2 Order data
Model number
Short description
Figure
Temperature measurement
X90AT910.04-00
X90 mobile option board AT, 4 resistance measurement inputs,
PT1000, optional DI, 9 to 32 VDC, sink/source, optional AI, 0 to
10 V / 0 to 32 V, 0 to 20 mA, optional PWM output, 9 to 32 VDC,
10 mA, 1 kHz, configuration using software
X90AT910.08-00
X90 mobile option board AT, 8 resistance measurement inputs,
PT1000, optional DI, 9 to 32 VDC, sink/source, optional AI, 0 to
10 V / 0 to 32 V, 0 to 20 mA, optional PWM output, 9 to 32 VDC,
10 mA, 1 kHz, configuration using software
Table 37: X90AT910.04-00, X90AT910.08-00 - Order data
Inputs and outputs - Overview
X90AT910.0x-00
Output
Input
Multifunction I/O
Quantity
PWM
Digital
Analog
PWM signal Temperature
Analog
Counter
functionality
Digital
MF-AT
4/8
X
X
X
X