X90 mobile modules
X90 mobile system User's manual V 1.20 - Translation of the original manual
173
RmsAccEnvelope
Name:
RmsAccEnvelope01 to RmsAccEnvelope04
Registers for reading the RMS value of the envelope signal of the respective channel.
RmsAccEnvelope is formed from the envelope signal of the oscillation acceleration from the configured minimum
frequency (
"MinFrequencyEnvelope" on page 187
) to the configured maximum frequency (
"MaxFrequencyEn-
velope" on page 185
).
Format
Unit
Value on overflow
REAL
mg
1.7
RmsAccRaw
Name:
RmsAccRaw01 to RmsAccRaw04
Registers for reading the acceleration RMS value of the respective channel.
RmsAccRaw is formed from the raw signal of the oscillation acceleration from the configured minimum frequency
(
"MinFrequencyRaw" on page 188
) to the configured maximum frequency (
"MaxFrequencyRaw" on page 186
).
Format
Unit
Value on overflow
REAL
mg
1.7
RmsHighFrequency
Name:
RmsHighFrequency01 to RmsHighFrequency04
Registers for reading the high-pass RMS value of the respective channel.
RmsHighFrequency is formed from the high-pass filtered input signal of the oscillation acceleration in the frequency
domain between the value set in register
"HighFrequencyConfig" on page 185
and 10 kHz.
Format
Unit
Unit on overflow
REAL
mg
256000.0