Mechanical and electrical configuration
18
X90 mobile system User's manual V 1.20 - Translation of the original manual
3.5 Installation instructions
Important!
Unused connectors (CMC header and M12 circular connector) must be sealed with suitable covers! It
is not recommended to install the X90 mobile system with the connection facing upwards. This could
lead to permanent stress on the single core seals due to standing water, ice or chemicals.
To ensure sufficient air circulation, a specified clearance of 10 mm must be provided. The clearances in the following
chapter "Installation with straight connector" apply to the connector side.
The clearance is valid for all X90 mobile variants.
Min. 10 mm
spacing
Min. 10 mm
spacing
Min. 10 mm
spacing
Min. 10 mm
spacing
Figure 5: Installation instructions