3. Connect the plug-in connector to the appropriate
Door 1 Terminal [pentagons 10, 11]
on
the AVH21 and connect and terminate the door lock end as appropriate. NOTE: Door 1
relays should not be paralleled with Door 2 relays.
4. If
using
the
+/- Terminal [pentagon 10]
, set the
12V/24V Switch [pentagon 12]
to the
proper position.
5. In larger systems using multiple AVH21’s, the Door 1 terminals can be used to activate
different door locks in different areas. The various Doors will appear in the KP21 Keypad
Main Menu under
DOOR
. If only one AVH21 is used, two Doors will appear in the menu, if
two AVH21’s are used, there will be four Doors available, and if using three AVH21’s, there
will be six Doors in the Menu.
a) AVH21 #1 controls Doors 1 & 2 (1=1; 2=2)
b) AVH21 #2 controls Doors 3 & 4 (1=3; 2=4)
c) AVH21 #3 controls Doors 5 & 6 (1=5; 2=6)
Door 2
The Door 2 cluster features two latching relays. The
Dry Contact Terminal [pentagon 14]
would
typically be used with a door lock mechanism that provides voltage for activation by a remote
switch. The
+/- Terminal [pentagon 13]
would typically be used with a door lock mechanism that
requires external voltage to activate. The
+/- Terminal [pentagon 13]
has a selectable output
voltage of 12 or 24 VDC.
1. Using 24AWG two-conductor stranded wire, strip approximately ¼” and twist the ends until
there are no loose strands that can cause shorts.
2. Insert the twisted ends into the appropriate slots on the included plug-in connectors and
tighten with a small blade screwdriver. Pull the wire slightly to confirm connection. Check
polarity on both ends. NOTE: Polarity on the AVH21
Dry Contact [pentagon 14]
end is not
critical. The Polarity of the Door 1
+/- Terminal [pentagon 13]
must be correct or the door
lock device will not function properly and may be damaged.
3. Connect the plug-in connector to the appropriate
Door 2 Terminal [pentagons 13, 14]
on
the AVH21 and connect and terminate the door lock end as appropriate.
4. If
using
the
+/- Terminal [pentagon 13]
, set the
12V/24V Switch [pentagon 15]
to the
proper position.
5. In larger systems using multiple AVH21’s, the Door 2 terminals can be used to activate
different door locks in different areas. The various Doors will appear in the KP21 Keypad
Main Menu under
DOOR
. If only one AVH21 is used, two Doors will appear in the menu, if
two AVH21’s are used, there will be four Doors available, and if using three AVH21’s, there
will be six Doors in the Menu.
a. AVH21 #1 controls Doors 1 & 2 (1=1; 2=2)
b. AVH21 #2 controls Doors 3 & 4 (1=3; 2=4)
c. AVH21 #3 controls Doors 5 & 6 (1=5; 2=6)
WPS21 CONNECTIONS
AVH21 Power Connections
See section:
AVH21 Connections/Power In
.
AC Input
1. Connect the supplied power cord and plug it into an unswitched 120V AC outlet after all
system connections have been made and confirmed. Use the supplied cord or contact or
contact Audioaccess for information on how to acquire a proper replacement.
KP21 SETUP
Keypad Address Settings
Before making any connections to a KP21 Keypad, it must be configured for its unique network
address. This address tells the system which button in which zone is initiating a specific
command or function. The network address is set using the six position
DIP Switch [hexagon
Содержание AVR21EN
Страница 1: ...1 INSTALLATION INSTRUCTIONS...
Страница 41: ...41 AVR21ENR1 FUNCTION LIST Figure 8 AVR21ENR1 Button Locations...
Страница 156: ...156 KP21R ZONE REMOTE FUNCTION LIST Figure 84 KP21R Button Locations...
Страница 159: ...159 Figure 86 Typical Three Zone System...
Страница 161: ...161 Figure 87 Typical Hub System...
Страница 164: ...164 Figure 90 Multiple Hub Power Connections...