139
9.
Power IN:
1, four position plug-in terminal for connection to WPS21 Power Supply Hub
AVH21 A/V Hub Power Terminal [rectangle 5]
for DC voltage to power the AVH21 Hub and
connected keypads.
10.
Door 1 12/24VDC Latching Trigger Output:
1, two position plug-in terminal connects to a
voltage activated door lock. Selectable 12 or 24 VDC output allows remote control of voltage
activated door locks.
11.
Door 1 Dry Contact Latching Trigger Output:
1, two position plug-in terminal connects to a
remote door lock that requires a latching dry contact closure to activate. (This type of door
lock system would provide its own power to activate when the circuit is closed, therefore 0
voltage, or a ‘dry closure’ is used.)
12.
Door 1 12/24 VDC Selector:
1, two position switch sets the output voltage for the
Door 1
12/24 VDC Latching Trigger Output [pentagon 10]
. Set to 12V for door locks requiring up
to 12 volts, set to 24V for door locks requiring between 12 and 24 volts.
13.
Door 2 12/24VDC Latching Trigger Output:
1, two position plug-in terminal connects to a
voltage activated door lock. Selectable 12 or 24 VDC output allows remote control of voltage
activated door locks.
14.
Door 2 Dry Contact Latching Trigger Output:
1, two position plug-in terminal connects to a
remote door lock that requires a latching dry contact closure to activate. (This type of door
lock system would provide its own power to activate when the circuit is closed, therefore 0
voltage, or a ‘dry closure’ is used.)
15.
Door 2 12/24 VDC Selector:
1, two position switch sets the output voltage for the
Door 2
12/24 VDC Latching Trigger Output [pentagon 13]
. Set to 12V for door locks requiring up
to 12 volts, set to 24V for door locks requiring between 12 and 24 volts.
16.
Uplink Terminal:
1, RJ45 jack connects to the
Multiroom Link [circle 30]
on the AVR21EN
rear panel. This link allows two-way communication of zone/system control from connected
KP21 Keypads. Digital audio data for common source audio distribution is also provided via
this connection. The Uplink terminal connects to the
EXPANSION/AUX KP Terminal
[pentagon 6]
on the previous sequential AVH21 to loop control and digital audio data when
using multiple AVH21’s in expanded systems. (i.e. AVH21 Hub 1
EXPANSION/AUX KP
Terminal [pentagon 6]
connects to the AVH21 Hub 2
Uplink Terminal [pentagon 16]
.)
Содержание AVR21EN
Страница 1: ...1 INSTALLATION INSTRUCTIONS...
Страница 41: ...41 AVR21ENR1 FUNCTION LIST Figure 8 AVR21ENR1 Button Locations...
Страница 156: ...156 KP21R ZONE REMOTE FUNCTION LIST Figure 84 KP21R Button Locations...
Страница 159: ...159 Figure 86 Typical Three Zone System...
Страница 161: ...161 Figure 87 Typical Hub System...
Страница 164: ...164 Figure 90 Multiple Hub Power Connections...