AudioFile SCX user manual
271
Revision
0.91
This parameter determines the way the machine servos into lock. The most
common method is to servo up from 1 frame behind. However, this is not
suitable for some machines, which will be unable to lock by this method. If the
machine hovers between zero error and 1 frame error, try an alternate servo
type. NOTE: The servo software can make automatic changes to this value.
Slew limit (frames)
Maximum number of frames of error which will be made up by servoing rather
than shuttling.
Error above this value will cause the machine to go into shuttle mode rather
than servo mode.
Lock correction (frames)
Number of frames a machine will ‘jump’ when releasing.
The parameter allows correction for machines who’s reported position “jumps”
when it is released from servoing. Adjustment of this parameter is normally
not necessary.
o Lock Wait
N
when zero error is achieved before machine
decrease machine lock up time in some
hold zero error for some time before actually reporting loc
Servo Hold (frames)
Hold servoing for this number of frames before issuing play.
Once zero error has been achieved, the MCS will continue to servo at play
peed for the time specified. This can help avoid situations where the
machine is servoed up from behind and is possibly speeding up when
released and therefore could be i
Release Hold off (frames)
Number of frames to wait after releasing before LOCK is confirmed.
his parameter controls the last stage of the servo process for a machine.
After zero error is achieved and the machine is released, the MCS will wait for
e specified time before lock is confirmed. This gives more leeway for final
errors to be corrected if required. Adjusting this value may help if lock errors
are observed after lock has been reported.
N
on zero means assume lock
reports servo lock.
Setting this to a non zero value will
cases (for example 7030). This is because certain machines may achieve and
k.
s
nto the next frame when released.
T
th
Jan 2008
Содержание AudioFile SC/X
Страница 1: ...AudioFile SCX user manual 1 Revision 0 91 Jan 2008 ...
Страница 214: ...You can then enter the fade time AudioFile SCX user manual 214 Revision 0 91 Jan 2008 ...
Страница 226: ...AudioFile SCX user manual 226 Revision 0 91 Jan 2008 ...
Страница 296: ...Display type hould be set to Timecode ts defaults S Projec AudioFile SCX user manual 296 Revision 0 91 Jan 2008 ...
Страница 302: ...AudioFile SCX user manual 302 Revision 0 91 Jan 2008 ...
Страница 388: ...AudioFile SCX user manual 388 Revision 0 91 Jan 2008 ...