Serial Communications
|
A-19
61/97
Alarm_flags
IQ
Which oxygen alarm has been set and why
bit 0
– high oxygen, process alarm
bit 1
– low oxygen, process alarm
bit 2
– high combustible, process alarm
bit 3
– high methane, process alarm
bit 4
– high oxygen, alarm #2
bit 5
– low oxygen, alarm #2
bit 6
– high combustible, alarm #2
bit 7
– high methane, alarm #2
bit 8
– high oxygen, alarm #3
bit 9
– low oxygen, alarm #3
bit 10
– high combustible, alarm #3
bit 11
– high methane, alarm #3
bit 12
– Future use
bit 13
- Out of Range, for SA/F sensor
bit 14
- Future use
bit 15
- Future use
Read only
Alarm_flags
S2
Which oxygen alarm has been set and why
bit 0
– low oxygen, alarm #3
bit 1
– high oxygen, alarm #3
bit 2
– low oxygen, alarm #4
bit 3
– high oxygen, alarm #4
bit 4
– high combustion, alarm #5
bit 5
– high combustion, alarm #6
bit 6
– high methane, alarm #7
bit 7
– high methane, alarm #8
bit 8
– Future use
bit 9
– Future use
bit 10
– Future use
bit 11
– Future use
bit 12
– Future use
bit 13
- Future use
bit 14
- Future use
bit 15
- Future use
Read only
Содержание Thermox WDG Insitu
Страница 12: ...xii Thermox Series 2000 WDG Insitu This page intentionally left blank...
Страница 20: ...1 8 Thermox Series 2000 WDG Insitu Analyzer This page intentionally left blank...
Страница 24: ...2 4 Thermox Series 2000 WDG Insitu Analyzer This page intentionally left blank...
Страница 28: ...3 4 Thermox Series 2000 WDG Insitu Analyzer Figure 3 2 Insitu senor mounting...
Страница 44: ...3 20 Thermox Series 2000 WDG Insitu Analyzer Figure 3 19 Sensor connections...
Страница 51: ...Installation and Start Up 3 27 Figure 3 23 Series 2000 2 Wire RS 485 communications connections...
Страница 53: ...Installation and Start Up 3 29 Figure 3 24 Series 2000 4 wire RS 485 communication connections...
Страница 114: ...6 16 Thermox Series 2000 WDG Insitu Analyzer This page intentionally left blank...
Страница 128: ...7 14 Thermox Series 2000 WDG Insitu Analyzer This page intentionally left blank...
Страница 154: ...A 26 Thermox Series 2000 WDG Insitu Analyzer This page intentionally left blank...
Страница 158: ...B 4 Thermox Series 2000 WDG Insitu Analyzer This page intentionally left blank...
Страница 164: ...D 2 Thermox Series 2000 WDG Insitu Analyzer This page intentionally left blank...