![ABB FSO-21 Скачать руководство пользователя страница 143](http://html.mh-extra.com/html/abb/fso-21/fso-21_user-manual_2728143.webp)
Safety functions 143
SLS with time monitoring and speed above monitored speed
The operation of the SLS function with time monitoring is described in the time
diagram and table below. For configuration, see section
on page
.
A
SLS trip limit positive (parameter
B
,
C
SLS time delay (parameter
): Delay for forcing to start SLS monitoring.
Motor speed
Time
1
5
4
3
2
6
A
B
C
SLS request
SLS monitoring
SLS indication
Manual
acknowledgment