176 Safety functions
4
The Variable SLS request is received again from the safety PLC (for example, 50%).
The FSO sends a request to the drive to ramp down the motor speed to the new speed
limit.
5
After time B has elapsed, the drive starts to ramp down the motor speed. SAR1
parameter
defines the deceleration ramp. The FSO starts to monitor the ramp
with SAR1 parameters (
). The Variable SLS indication goes off (see
also section
How to configure limit hit situations
on page
Note
: The FSO continues to monitor the existing Variable SLS limits until the new
speed limit has been reached.
6
The new motor speed has been reached and the FSO starts to monitor the motor
speed according to the new SLS limits. The Variable SLS active indication goes on.
7
The Variable SLS request is received again from the safety PLC (100%). The FSO
sends a request to the drive. The FSO starts to monitor the motor speed according to
the new SLS limits.
8
After time B has elapsed and if the motor speed
is lower than the new speed limit, the
drive accelerates the motor speed to the requested speed.
9
The Variable SLS request is removed from the safety PLC (acknowledgement method
is manual or from a safety PLC).
Note
: If automatic acknowledgement is used, the Variable SLS monitoring is also
ended.
10
The Variable SLS is acknowledged and the FSO stops the SLS monitoring. The drive
continues with the speed reference set by the user. The Variable SLS indication
(parameter
) goes off.
Step Description
Содержание FSO-21
Страница 1: ... OPTIONS FOR ABB DRIVES FSO 21 safety functions module User s manual ...
Страница 4: ......
Страница 16: ...16 Safety instructions ...
Страница 34: ...34 Safety information and considerations ...
Страница 52: ...52 Overview ...
Страница 236: ...236 PROFIsafe ...
Страница 265: ...PROFIsafe 265 2 Select your CPU from the list 3 Install the FENA 21 GSDML file ...
Страница 275: ...PROFIsafe 275 20 In ABB_Drive FB add blocks DPRD_DAT and DPWR_DAT 21 Insert values to blocks ...
Страница 282: ...282 PROFIsafe 5 To read the diagnostic messages select the I O Device Diagnostics tab ...
Страница 286: ...286 PROFIsafe ...
Страница 304: ...304 Installation ...
Страница 400: ...400 Configuration ...
Страница 488: ...488 Verification and validation ...
Страница 506: ...506 Fault tracing ...
Страница 514: ...514 Maintenance ...
Страница 536: ...536 Technical data ...
Страница 538: ...538 Dimension drawings 3AXD50000018513 ...