![ABB FSO-21 Скачать руководство пользователя страница 230](http://html.mh-extra.com/html/abb/fso-21/fso-21_user-manual_2728230.webp)
230 PROFIsafe
Note
: When the FB module is installed to the drive for the first time, you must set the
value of parameter
51/54.02
to one of the PROFINET profiles (value
11
if a drop-
down list is unavailable) and reboot the FB module with parameter
51/54.27
. Only
after this, the rest of the parameters in group 51/54 get the correct texts and options.
If required, you must reconnect Drive composer pro to the drive to get the parameters
show up correctly (select
Refresh
from the
New
menu).
See the FB module user’s manual and the drive firmware manual for all necessary
parameter settings and detailed instructions on how to control the drive and motor
using the normal PROFINET cyclic communication.
Configuring the FSO module
Set the FSO module parameters as described in section
.
51/54.02
FBA A/B PAR2
(PROTOCOL/
PROFILE)
Selects one of the PNIO profiles.
11
PNIO ABB Pro
Profile PNIO ABB Pro is selected
51/54.03
FBA A/B PAR2
(COMMRATE)
Sets the Ethernet communication rate.
0
Auto
Ethernet communication rate is negotiated
automatically by the device.
51/54.04…13 IP
CONFIGURATI
ON
The user can set the IP configuration for the
network in these parameters or in the PLC
project.
Static IP
0
51/54.20
Telegram type
Shows the telegram type for the selected I/O
communication.
This parameter is read-only.
4
PPO4
PPO Type 4
51/54.21
Alarm disable
Enables/disables the sending of diagnostic
messages to the PROFINET network.
0
Enabled
Diagnostic messages are sent.
51/54.27
FBA A/B PAR
REFRESH
Validates any changed FB module configuration
settings and reboots the FB module taking all the
changes to the drive parameters in use. After
refreshing, the value reverts automatically to
Done (0).
Note
: This parameter cannot be changed while
the drive is running.
1
REFRESH
Refreshing.
Index
Name/Value
Description
Example
value
Содержание FSO-21
Страница 1: ... OPTIONS FOR ABB DRIVES FSO 21 safety functions module User s manual ...
Страница 4: ......
Страница 16: ...16 Safety instructions ...
Страница 34: ...34 Safety information and considerations ...
Страница 52: ...52 Overview ...
Страница 236: ...236 PROFIsafe ...
Страница 265: ...PROFIsafe 265 2 Select your CPU from the list 3 Install the FENA 21 GSDML file ...
Страница 275: ...PROFIsafe 275 20 In ABB_Drive FB add blocks DPRD_DAT and DPWR_DAT 21 Insert values to blocks ...
Страница 282: ...282 PROFIsafe 5 To read the diagnostic messages select the I O Device Diagnostics tab ...
Страница 286: ...286 PROFIsafe ...
Страница 304: ...304 Installation ...
Страница 400: ...400 Configuration ...
Страница 488: ...488 Verification and validation ...
Страница 506: ...506 Fault tracing ...
Страница 514: ...514 Maintenance ...
Страница 536: ...536 Technical data ...
Страница 538: ...538 Dimension drawings 3AXD50000018513 ...