![ABB FSO-21 Скачать руководство пользователя страница 58](http://html.mh-extra.com/html/abb/fso-21/fso-21_user-manual_2728058.webp)
58 Safety functions
Limit hit
: If the motor speed hits a ramp monitoring limit, the FSO module activates
the STO function and generates an event. The user can select the event type
(warning, fault or event) with parameter
.
Safety function indications
Safety functions have the following indications:
• Request indication, which is shown in the control panel or in the event log (stopping
functions (STO, SS1, SSE) and POUS)
• Digital output indication, see
on page
• Status bit indication, see
on page
and
on page
Request indication
The safety function request indication for stopping functions (STO, SS1, SSE) and
POUS is activated immediately when a safety function is requested. The type of the
indication (event type) is selected with parameter
Note:
For the POUS function, the request indication is always a warning if activated
when the drive is not modulating, and the indication is a fault, when the drive is
modulating, see
on page
.
FSO digital output indication
FSO digital outputs can be configured for indication or for controlling, eg, safety door
locking/unlocking. Digital output indications for the safety functions are explained in
connection with the safety function descriptions in chapter
, in
on page
, and in
Parameters for FSO inputs and outputs
.
If configured to a function output parameter, the digital output is controlled to change
state immediately when a safety function is requested. If configured to a function
completed output parameter, the digital output is controlled to change state when a
safety function is completed.
Note:
A logic state of output indication signals can be configured to be active low or
active high.
See also chapter PROFIsafe for
on page
.
E
Scaling speed: value of parameter
. Speed value that the
FSO module uses as a reference point in ramp time calculations. This value and the
minimum (A), target (B) and maximum (C) ramp times define fixed slopes for the
deceleration ramps that are used in ramp monitoring.
Common for all ramps SARn, n = 0…1.
Содержание FSO-21
Страница 1: ... OPTIONS FOR ABB DRIVES FSO 21 safety functions module User s manual ...
Страница 4: ......
Страница 16: ...16 Safety instructions ...
Страница 34: ...34 Safety information and considerations ...
Страница 52: ...52 Overview ...
Страница 236: ...236 PROFIsafe ...
Страница 265: ...PROFIsafe 265 2 Select your CPU from the list 3 Install the FENA 21 GSDML file ...
Страница 275: ...PROFIsafe 275 20 In ABB_Drive FB add blocks DPRD_DAT and DPWR_DAT 21 Insert values to blocks ...
Страница 282: ...282 PROFIsafe 5 To read the diagnostic messages select the I O Device Diagnostics tab ...
Страница 286: ...286 PROFIsafe ...
Страница 304: ...304 Installation ...
Страница 400: ...400 Configuration ...
Страница 488: ...488 Verification and validation ...
Страница 506: ...506 Fault tracing ...
Страница 514: ...514 Maintenance ...
Страница 536: ...536 Technical data ...
Страница 538: ...538 Dimension drawings 3AXD50000018513 ...