442 Parameters
SAFEIO.12 Cascade A
Sets the cascade connection A for the FSO
module. For each FSO module in cascade
A, the digital input connected to the safety
function is also internally connected to the
corresponding digital output of the FSO
module (digital input -> digital output). This
resembles a master/follower connection.
See section
on page
None
Not cascaded
X113:1 & X114:1 ->
X113:7 & X114:7
Redundant cascade X113:1 & X114:1 ->
X113:7 & X114:7
X113:2 & X114:2 ->
X113:8 & X114:8
Redundant cascade X113:2 & X114:2 ->
X113:8 & X114:8
X113:3 & X114:3 ->
X113:9 & X114:9
Redundant cascade X113:3 & X114:3 ->
X113:9 & X114:9
X113:1 -> X113:7
Single cascade X113:1 -> X113:7
X113:2 -> X113:8
Single cascade X113:2 -> X113:8
X113:3 -> X113:9
Single cascade X113:3 -> X113:9
X114:1 -> X114:7
Single cascade X114:1 -> X114:7
X114:2 -> X114:8
Single cascade X114:2 -> X114:8
X114:3 -> X114:9
Single cascade X114:3 -> X114:9
SAFEIO.13 Cascade B
Sets the cascade connection B for the FSO
module.
For each FSO module in cascade
B, the digital input connected to the safety
function is also internally connected to the
corresponding digital output of the FSO
module (digital input -> digital output).
See section
on page
None
Not cascaded
X113:1 & X114:1 ->
X113:7 & X114:7
Redundant cascade X113:1 & X114:1 ->
X113:7 & X114:7
X113:2 & X114:2 ->
X113:8 & X114:8
Redundant cascade X113:2 & X114:2 ->
X113:8 & X114:8
X113:3 & X114:3 ->
X113:9 & X114:9
Redundant cascade X113:3 & X114:3 ->
X113:9 & X114:9
X113:1 -> X113:7
Single cascade X113:1 -> X113:7
X113:2 -> X113:8
Single cascade X113:2 -> X113:8
X113:3 -> X113:9
Single cascade X113:3 -> X113:9
X114:1 -> X114:7
Single cascade X114:1 -> X114:7
X114:2 -> X114:8
Single cascade X114:2 -> X114:8
X114:3 -> X114:9
Single cascade X114:3 -> X114:9
Index
Name/Value
Description
Factory
default
Содержание FSO-21
Страница 1: ... OPTIONS FOR ABB DRIVES FSO 21 safety functions module User s manual ...
Страница 4: ......
Страница 16: ...16 Safety instructions ...
Страница 34: ...34 Safety information and considerations ...
Страница 52: ...52 Overview ...
Страница 236: ...236 PROFIsafe ...
Страница 265: ...PROFIsafe 265 2 Select your CPU from the list 3 Install the FENA 21 GSDML file ...
Страница 275: ...PROFIsafe 275 20 In ABB_Drive FB add blocks DPRD_DAT and DPWR_DAT 21 Insert values to blocks ...
Страница 282: ...282 PROFIsafe 5 To read the diagnostic messages select the I O Device Diagnostics tab ...
Страница 286: ...286 PROFIsafe ...
Страница 304: ...304 Installation ...
Страница 400: ...400 Configuration ...
Страница 488: ...488 Verification and validation ...
Страница 506: ...506 Fault tracing ...
Страница 514: ...514 Maintenance ...
Страница 536: ...536 Technical data ...
Страница 538: ...538 Dimension drawings 3AXD50000018513 ...