![ABB FSO-21 Скачать руководство пользователя страница 207](http://html.mh-extra.com/html/abb/fso-21/fso-21_user-manual_2728207.webp)
PROFIsafe 207
Note
: The states of all FSO inputs and outputs are shown in the PROFIsafe
message. These states also show the states of SBC outputs and feedback inputs.
ABB_PS2 profile F-Output user data
This table shows the bit order of the F-Output data, which is included in the
PROFIsafe message sent to the FSO module from the safety PLC. For all the bits in
the F-Output data, one (1) means active and zero (0) non-active.
Intege
r16
6
Safe_speed_MSB
The current motor speed value from FSO (MSB).
Intege
r16
7
Safe_speed_LSB
The current motor speed value from FSO (LSB).
*)
The safety PLC must ignore the value of the reserved bits. This ensures the compatibility
with future versions of the PROFIsafe profile where the reserved bits may be used.
Type
Octet Bit Name
Description
Unsig
ned16
(used
as
bits)
0
0
SLS2_request
SLS2 (Safely-limited speed) activation requested by
the controller.
1
SLS1_request
SLS1 (Safely-limited speed) activation requested by
the controller.
2
Reserved
*)
Must not be used (must be 0).
3
Reserved
*)
Must not be used (must be 0).
4
SS1_request
SS1 (Safe stop 1) activation requested by the
controller.
5
SSE_request
SSE (Safe stop emergency) activation requested by
the controller.
6
POUS_request
POUS (Prevention of unexpected start-up)
activation request by the controller.
7
STO_request
STO (Safe torque off) activation requested by the
controller.
Unsig
ned16
(used
as
bits)
1
0
SDI_N_ activate
SDI_N (Safe direction) activation requested by the
controller.
1
SDI_P_ activate
SDI_P (Safe direction) activation requested by the
controller.
2
Reserved
*)
Must not be used (must be 0).
3
Reserved
*)
Must not be used (must be 0).
4
Reserved
*)
Must not be used (must be 0).
5
Reserved
*)
Must not be used (must be 0).
6
SLS4_request
SLS4 (Safely-limited speed) activation requested by
the controller.
7
SLS3_request
SLS3 (Safely-limited speed) activation requested by
the controller.
Type
Octet Bit Name
Description
Содержание FSO-21
Страница 1: ... OPTIONS FOR ABB DRIVES FSO 21 safety functions module User s manual ...
Страница 4: ......
Страница 16: ...16 Safety instructions ...
Страница 34: ...34 Safety information and considerations ...
Страница 52: ...52 Overview ...
Страница 236: ...236 PROFIsafe ...
Страница 265: ...PROFIsafe 265 2 Select your CPU from the list 3 Install the FENA 21 GSDML file ...
Страница 275: ...PROFIsafe 275 20 In ABB_Drive FB add blocks DPRD_DAT and DPWR_DAT 21 Insert values to blocks ...
Страница 282: ...282 PROFIsafe 5 To read the diagnostic messages select the I O Device Diagnostics tab ...
Страница 286: ...286 PROFIsafe ...
Страница 304: ...304 Installation ...
Страница 400: ...400 Configuration ...
Страница 488: ...488 Verification and validation ...
Страница 506: ...506 Fault tracing ...
Страница 514: ...514 Maintenance ...
Страница 536: ...536 Technical data ...
Страница 538: ...538 Dimension drawings 3AXD50000018513 ...