![ABB FSO-21 Скачать руководство пользователя страница 523](http://html.mh-extra.com/html/abb/fso-21/fso-21_user-manual_2728523.webp)
Technical data 523
FSE-31 pulse encoder interface module
The FSE-31 module is a type B safety component as defined in IEC 61508-2.
The FSE-31 data related to safety standards IEC 61508, EN/IEC 61800-5-2,
EN ISO 13849-1 and EN/IEC 62061 is listed below.
The maximum useful mission time (
T
m
) for the FSE module is 20 years. After 20
years, the module must be replaced.
The given safety data is applicable with proof test interval T1 = 20 years (high
demand and continuous mode of operation), or T1 = 2 or 5 years (low demand mode
of operation). Make sure that the proof test is performed within this time (see also
section
Proof test intervals during operation
).
1-ch. DO,
pulses
2-ch. DO,
pulses
1-ch. DO,
no
pulses
2-ch. DO,
no
pulses
STO
output
Speed
estimate,
worst
case
values
Speed
measure-
ment
with
FSE-31
SIL
3
3
1
3
3
3
3
PL
d
e
c
e
e
e
e
PFH (1/h)
(T1 = 20 a)
6.3E-10
1.7E-10
4.9E-09
2.2E-10
1.8E-11
1.0E-08
6.4E-08
PFD
avg
(T1 =2 a)
3.8E-07
1.5E-06
2.3E-06
2.4E-06
1.6E-07
1.4E-04
9.7E-05
PFD
avg
(T1 =5 a)
9.6E-07
3.7E-06
5.7E-06
5.9E-06
3.9E-07
2.7E-04
9.9E-04
PFD
avg
(T1 = 20 a)
3.8E-06
1.5E-05
2.3E-05
2.4E-05
1.6E-06
5.0E-04
-
MTTF
D
(a)
2412
2406
2412
2412
321699
164
3360
HFT
0
1
0
1
1
0
1
Cat.
2
3
1
3
3
3
3
SFF (%)
99.5
97.5
96.2
96.6
99.4
99.0
96.8
DC (%)
98.7
92.9
89.6
90.7
99.0
99.0
96.6
3AXD10001287182 C
SIL PL
SFF
(%)
PFH
(T1 = 20 a)
(1/h)
PFD
avg
(T1 = 2 a)
PFD
avg
(T1 = 5 a)
MTTF
D
(a)
DC
(%)
SC Cat. HFT CCF
3
e
96.84
6.36E-08
9.73E-05
9.85E-04
3360
97
3
3
1
80
3AXD10000289254 L
Содержание FSO-21
Страница 1: ... OPTIONS FOR ABB DRIVES FSO 21 safety functions module User s manual ...
Страница 4: ......
Страница 16: ...16 Safety instructions ...
Страница 34: ...34 Safety information and considerations ...
Страница 52: ...52 Overview ...
Страница 236: ...236 PROFIsafe ...
Страница 265: ...PROFIsafe 265 2 Select your CPU from the list 3 Install the FENA 21 GSDML file ...
Страница 275: ...PROFIsafe 275 20 In ABB_Drive FB add blocks DPRD_DAT and DPWR_DAT 21 Insert values to blocks ...
Страница 282: ...282 PROFIsafe 5 To read the diagnostic messages select the I O Device Diagnostics tab ...
Страница 286: ...286 PROFIsafe ...
Страница 304: ...304 Installation ...
Страница 400: ...400 Configuration ...
Страница 488: ...488 Verification and validation ...
Страница 506: ...506 Fault tracing ...
Страница 514: ...514 Maintenance ...
Страница 536: ...536 Technical data ...
Страница 538: ...538 Dimension drawings 3AXD50000018513 ...