![ABB FSO-21 Скачать руководство пользователя страница 339](http://html.mh-extra.com/html/abb/fso-21/fso-21_user-manual_2728339.webp)
Configuration 339
Encoder or FSE failure situations
The STO with speed limit activated SBC function (parameter
=
Speed limit
) requires the exact motor speed, and when this is not available,
the FSO module starts to use the
Delayed brake
selection (parameter
Delayed brake
).
If parameter
FSE diagnostic failure reaction
STO
, the FSO module
goes into the Fail-safe mode and actives the STO with speed limit activated SBC
function with
Delayed brake
:
•
If parameter
is positive, the FSO activates the SBC
after this time has elapsed from the STO activation.
•
is negative or zero, the FSO actives the
SBC when the encoder failure occurs.
If parameter
FSE diagnostic failure reaction
=
No STO
, and there are
no active safety functions, the FSO module sends a warning to the drive. If there are
active safety functions when the FSO module detects the failure, the FSO module
goes into the Fail-safe mode and actives the STO with speed limit activated SBC
function with
Delayed brake
(see above).
FSE diagnostic failure reaction
=
Est switch not active
load
, the FSO module continues operation by using the estimated motor speed until
the encoder failure is fixed and the exact motor speed is available again.
Note:
Safe
speed estimate cannot be used with a DCS880 drive.
• If the encoder failure occurs
before
the STO function is activated, the FSO
continues operation using the estimated motor speed and activates the STO and
SBC function with
Delayed brake
(see section
How to configure SBC after STO
) when the STO function request is received.
• If the encoder failure occurs
while
the STO function is already active, but the
has not been reached yet, the FSO module starts to use the
Delayed
brake
and activates the SBC accordingly:
•
If parameter
is positive, the FSO activates the SBC
after this time has elapsed from the STO activation.
•
If parameter
is negative or zero, the FSO activates
the SBC when the encoder failure occurs.
Содержание FSO-21
Страница 1: ... OPTIONS FOR ABB DRIVES FSO 21 safety functions module User s manual ...
Страница 4: ......
Страница 16: ...16 Safety instructions ...
Страница 34: ...34 Safety information and considerations ...
Страница 52: ...52 Overview ...
Страница 236: ...236 PROFIsafe ...
Страница 265: ...PROFIsafe 265 2 Select your CPU from the list 3 Install the FENA 21 GSDML file ...
Страница 275: ...PROFIsafe 275 20 In ABB_Drive FB add blocks DPRD_DAT and DPWR_DAT 21 Insert values to blocks ...
Страница 282: ...282 PROFIsafe 5 To read the diagnostic messages select the I O Device Diagnostics tab ...
Страница 286: ...286 PROFIsafe ...
Страница 304: ...304 Installation ...
Страница 400: ...400 Configuration ...
Страница 488: ...488 Verification and validation ...
Страница 506: ...506 Fault tracing ...
Страница 514: ...514 Maintenance ...
Страница 536: ...536 Technical data ...
Страница 538: ...538 Dimension drawings 3AXD50000018513 ...