Technical data 519
For the environmental limits for the drive, refer to the hardware manual of your drive.
Safety functions
Relative humidity
5…95%, no condensation allowed. If corrosive gases are present,
the maximum allowed humidity is 60%.
Contamination levels
IEC 60721-3-x
No contaminants, conductive dust or corrosive dust allowed.
Use at least IP54 enclosure in an environment where conductive
dust or corrosive dust exists.
Chemical gases
Class 3C2
Class 1C2
Class 2C2
Solid particles
Class 3S2. No
conductive dust
allowed.
Class 1S3
Class 2S2
Vibration
IEC 60068-2-6,
Test Fc (2007-12)
Frequency range:
2…9 Hz: Constant deflection = 7 mm
9…200 Hz: Constant acceleration = 20 m/s
2
Shock
IEC 60068-2-27
Test Ea (2008-02)
Peak acceleration 50 m/s
2
. Pulse duration 30 ms, 3 pulses in each
direction with STO and SS1 functions activated.
Atmospheric pressure
70 … 106 kPa (0.7 … 1.05 atmospheres)
Stopping functions
STO
Safe torque off
SBC
Safe brake control
SS1
Safe stop 1
SSE
Safe stop emergency
Speed-related functions
SLS Safely-limited
speed
Variable SLS
Variable Safely-limited speed
SMS Safe
maximum
speed
SSM
Safe speed monitor
SDI
Safe direction
SAR
Safe acceleration range - SAR is used only for deceleration with SS1, SSE,
SDI and SLS and Variable SLS functions.
Other
POUS
Prevention of unexpected start-up
Operation
installed for
stationary use
Storage
in the protective
package
Transportation
in the protective
package
Содержание FSO-21
Страница 1: ... OPTIONS FOR ABB DRIVES FSO 21 safety functions module User s manual ...
Страница 4: ......
Страница 16: ...16 Safety instructions ...
Страница 34: ...34 Safety information and considerations ...
Страница 52: ...52 Overview ...
Страница 236: ...236 PROFIsafe ...
Страница 265: ...PROFIsafe 265 2 Select your CPU from the list 3 Install the FENA 21 GSDML file ...
Страница 275: ...PROFIsafe 275 20 In ABB_Drive FB add blocks DPRD_DAT and DPWR_DAT 21 Insert values to blocks ...
Страница 282: ...282 PROFIsafe 5 To read the diagnostic messages select the I O Device Diagnostics tab ...
Страница 286: ...286 PROFIsafe ...
Страница 304: ...304 Installation ...
Страница 400: ...400 Configuration ...
Страница 488: ...488 Verification and validation ...
Страница 506: ...506 Fault tracing ...
Страница 514: ...514 Maintenance ...
Страница 536: ...536 Technical data ...
Страница 538: ...538 Dimension drawings 3AXD50000018513 ...