![ABB FSO-21 Скачать руководство пользователя страница 323](http://html.mh-extra.com/html/abb/fso-21/fso-21_user-manual_2728323.webp)
Configuration 323
Parameter settings in the master FSO
Index
Name/Value Description
Sets the master/follower mode of the FSO module for both
cascade connections A and B separately. In this example, only
cascade connection A is used.
A = master,
B = master
This module is the master on cascade connection A.
Sets the cascade connection A for the FSO module. For each FSO
module in cascade A, the digital input connected to the safety
function is also internally connected to the corresponding digital
output of the module (digital input -> digital output).
X113:2 ->
X113:8
Single cascade X113:2 -> X113:8
Sets the cascade connection B for the FSO module.
None
Not cascaded
Sets the acknowledgement method used in the STO, SSE and
SS1 functions.
See section
on page
for more
information on different acknowledgement methods.
Manual
The FSO module reads the external STO acknowledgement signal
through the digital input defined by parameter
.
Sets the digital input that is connected to the primary input of the
SSE function.
In this example, this parameter sets the digital input that is used for
the activation of the SSE function in the master FSO.
DI X113:1 &
X114:1
Redundant input X113:1 & X114:1
Sets the digital input that is connected to the secondary input of the
SSE function.
In this example, this parameter sets the digital input that is used in
the cascade loop (Cascade A) to cascade the SSE function back to
the master FSO.
DI113:2
Single input X113:2
Sets the digital output that indicates the activity of the SSE
function. Active from the SSE request until the function has been
acknowledged.
In this example, this parameter sets the digital output that is used
in the cascade loop (Cascade A) to cascade the SSE function to
the follower FSOs.
DO X113:8
Single output X113:8
Sets the digital output that indicates the completion of the SSE
function.
In this example, output X113:7 is connected to the indication lamp.
DO X113:7
Single output X113:7
Содержание FSO-21
Страница 1: ... OPTIONS FOR ABB DRIVES FSO 21 safety functions module User s manual ...
Страница 4: ......
Страница 16: ...16 Safety instructions ...
Страница 34: ...34 Safety information and considerations ...
Страница 52: ...52 Overview ...
Страница 236: ...236 PROFIsafe ...
Страница 265: ...PROFIsafe 265 2 Select your CPU from the list 3 Install the FENA 21 GSDML file ...
Страница 275: ...PROFIsafe 275 20 In ABB_Drive FB add blocks DPRD_DAT and DPWR_DAT 21 Insert values to blocks ...
Страница 282: ...282 PROFIsafe 5 To read the diagnostic messages select the I O Device Diagnostics tab ...
Страница 286: ...286 PROFIsafe ...
Страница 304: ...304 Installation ...
Страница 400: ...400 Configuration ...
Страница 488: ...488 Verification and validation ...
Страница 506: ...506 Fault tracing ...
Страница 514: ...514 Maintenance ...
Страница 536: ...536 Technical data ...
Страница 538: ...538 Dimension drawings 3AXD50000018513 ...