15-3
IM 704510-01E
Specifications
3
2
1
4
5
6
7
8
9
10
11
12
13
14
15
15
Item
Specifications
Pulse width measurement • Measurement range
• When in time stamp mode: 6 ns to 20 ms
• When in hardware histogram mode: 6 ns to 3.2
µ
s
• When in inter-symbol interference analysis mode: 10 ns to 3.2
µ
s
• Measurement resolution
• When the polarity is set to
or
:
±
100 ps rms
*1
rising edge trigger error
*2
±
falling edge trigger error
*2
• When the polarity is
:
±
100 ps rms
*1
rising edge trigger error
*2
±
falling edge trigger error
*2
±
trigger level timing error
*3
• Accuracy
*4
• When the polarity is set to
or
:
Measurement resolution
±
trigger level timing error
±
(frequency stability of the time base
×
measured value)
±
1-ns systematic error
• When the polarity is
:
Measurement resolution
±
(frequency stability of the time base
×
measured value)
±
1-ns
systematic error
• Polarity: Select from
,
, and
(
only when in inter-symbol interference analysis
mode)
Period A & period B
• Measurement range
measurement
• When in time stamp mode: 6 ns to 20 ms
• When in hardware histogram mode: 6 ns to 3.2
µ
s
• Measurement resolution
±
100 ps rms
*1
±
2
×
trigger error
*2
• Accuracy
*4
Measurement resolution
±
(frequency stability of the time base
×
measured value)
±
300-ps
systematic error
• Slope: Select from A
↑
&B
↑
or A
↓
&B
↓
Period A & A-to-B time
• Measurement range
interval measurement
• When in time stamp mode
• Period measurement: 6 ns to 20 ms
• A-to-B time interval measurement: 0 ns to 20 ms
• When in hardware histogram mode
• Period measurement: 6 ns to 3.2
µ
s
• A-to-B time interval measurement: 0 ns to 3.2
µ
s
• Measurement resolution
• Period measurement:
±
100 ps rms
*1
±
2
×
trigger error
*2
• A-to-B time interval measurement:
±
100 ps rms
*1
±
A input trigger error
*2
±
B input trigger
error
*2
• Accuracy
*4
Period measurement: Measurement resolution
±
(frequency stability of the time base
×
measured
value)
±
300-ps systematic error
A-to-B time interval measurement:
Measurement resolution
±
trigger level timing error
±
(frequency stability of the time base
×
measured value)
±
1-ns systematic error
• Slope: Select from A
↑
&A
↑
B
↑
or A
↓
&A
↓
B
↑
• Continuous A-to-B time interval measurement condition: The time to the next A signal edge after
the A-to-B time interval measurement is greater than equal to 13 ns and the time from the
previous A signal edge is greater than or equal to 20 ns
*1 100 ps rms or the display resolution whichever is greater when in hardware histogram mode, inter-symbol interference
analysis mode, or time stamp mode using multi window display.
*2 The trigger error, A input trigger error, B input trigger error, rising edge trigger error, and falling edge trigger error defined by
the following equation.
X
2
+ W
2
+ E
2
n
SR
X: Input amplifier noise, W: Cross talk noise (0.01
×
the signal amplitude of the other channel [Vrms])
En: Noise in the signal being measured [Vrms], SR: Slew rate of the input signal [V/s]
*3 The trigger level timing error is defined by the following equation.
8mV
8mV
Slew rate of the start signal
Slew rate of the stop signal
Trigger level setting accuracy
Slew rate of the start signal
Slew rate of the stop signal
Trigger level setting accuracy
±
±
±
–
*4 Measured value under standard operating conditions as described in General Specifications after the warm-up time has
elapsed.
15.2 Measurement Functions (Measurement Items)