Command Function
Page
:FUNCtion/?
Sets the measurement function (voltage or current) or queries the
current setting.
16-26
[:VOLTage]
:RANGe/?
Sets the voltage measurement range or queries the current setting.
16-26
:AUTO/?
Turns ON/OFF the auto measurement range or queries the current
setting. 16-26
[:CURRent]
:RANGe/?
Sets the current measurement range or queries the current setting.
16-26
:AUTO/?
Turns ON/OFF the auto measurement range or queries the current
setting. 16-27
[:RESistance]
:RANGe/?
Sets the resistance measurement range (200 mΩ
, 2
Ω
, 20
Ω
to 200 M
Ω)
for resistance meter mode or queries the current setting.
16-27
:AUTO/?
Turns ON/OFF the auto measurement range or queries the current
setting. 16-27
:NPLC/?
Sets the measurement integration time or queries the current setting
(PLC conversion).
16-27
:ITIMe/?
Sets the measurement integration time or queries the current setting
(time conversion).
16-27
:DELay/?
Sets the measurement delay or queries the current setting.
16-28
:AVERage
[:STATe]/?
Turns ON/OFF the average function or queries the current setting.
16-28
:COUNt/?
Sets the average count or queries the current setting.
16-28
:ZERO
:AUTO/?
Turns ON/OFF the auto zero function or queries the current setting.
16-28
:EXECute
Executes zero calibration.
16-28
:REMote/?
Sets the wiring system (ON = 4W and OFF = 2W) or queries the
current setting.
16-28
Computation Commands (CALCulate Group)
[:CHANnel<n>]
:CALCulate
:NULL
[:STATe]/?
Turns ON/OFF the NULL computation function or queries the current
setting. 16-29
:OFFSet/?
Sets the NULL computation offset value or queries the current setting.
16-29
:MATH
[:STATe]/?
Turns ON/OFF the equation computation function or queries the current
setting. 16-29
:SELect/?
Sets the equation definition file or queries the current setting.
16-29
:CATalog?
Queries the list of equation definition files.
16-29
:DELete
Deletes an equation definition file.
16-29
:PARameter
:A/?
Sets equation parameter A or queries the current setting.
16-29
:B/?
Sets equation parameter B or queries the current setting.
16-30
:C/?
Sets equation parameter C or queries the current setting.
16-30
:LIMit
[:STATe]/?
Turns ON/OFF the comparison operation function or queries the current
setting. 16-30
:UPPer/?
Sets the upper limit for comparison or queries the current setting.
16-30
:LOWer/?
Sets the lower limit for comparison or queries the current setting.
16-30
16-9
IM 765601-01E
Communication Commands
3
2
1
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
App
Index
16.2 Commands