Sigma II User’s Manual
Chapter 9: Inspection, Maintenance, and Troubleshooting
9 - 24
A.86
A.86: Encoder Overheated
Display and Outputs
Note:
OFF:
Output transistor is OFF (alarm state).
Status and Remedy for Alarm
Alarm Outputs
Alarm Code Output
ALM Output
ALO1
ALO2
ALO3
OFF
OFF
OFF
OFF
Cause of the Problem
Solution
A
The ambient temperature of the
servomotor is high.
Alter conditions so that the ambi-
ent temperature goes below 40°C
B
Servomotor is operating under
overload.
Reduce load.
C
Circuit board (1PWB) defective.
Replace servo amplifier.
D
Encoder defective.
Replace servo amplifier.
During servomotor operation.
When the control panel
is turned ON.
A, B
C, D
Summary of Contents for SGMAH
Page 1: ...Sigma II Series Servo System User s Manual...
Page 2: ......
Page 4: ...ii This page intentionally left blank...
Page 6: ...iv This page intentionally left blank...
Page 10: ...Sigma II User s Manual Table of Contents Preface viii Notes...
Page 17: ...Sigma II User s Manual Table of Contents Preface xv C 6 Torque Control Mode C 9...
Page 18: ...Sigma II User s Manual Table of Contents Preface xvi...
Page 38: ...Sigma II User s Manual Chapter 2 Installation 2 10 NOTES...
Page 472: ...Sigma II User s Manual Appendix C Examples of Standard Connections C 10 Notes...
Page 487: ......